中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共17条,第1-10条 帮助

条数/页: 排序方式:
Study on optimization method of multi-point combined adhesive process for optical plane mirror 会议论文  OAI收割
Changchun, China, 2022-07-29
作者:  
Xiang-Ke, Zheng;  Shi-Fa, Kang;  Hua, Li;  Peng, Wang;  Xiaoyan, Li
  |  收藏  |  浏览/下载:12/0  |  提交时间:2023/03/02
Simulation and experimental investigation on linear expansion micro-stress assembly process of adhesive bonded mirror 会议论文  OAI收割
Kunming, China, 2021-12-07
作者:  
Zheng, Xiang-Ke;  Kang, Shi-Fa;  Wang, Peng;  Li, Hua;  Shu, Lin-Sen
  |  收藏  |  浏览/下载:74/0  |  提交时间:2022/04/27
Fe-substituted Ba-hexaaluminates oxygen carrier for carbon dioxide capture by chemical looping combustion of methane 期刊论文  OAI收割
AICHE JOURNAL, 2016, 卷号: 62, 期号: 3, 页码: 792-801
作者:  
Liu, Xin;  Zhang, Tao;  Tian, Ming;  Wang, Xiaodong;  Wang, Aiqin
  |  收藏  |  浏览/下载:11/0  |  提交时间:2019/06/20
Advanced astigmatism-corrected tandem Wadsworth mounting for small-scale spectral broadband imaging spectrometer (EI CONFERENCE) 会议论文  OAI收割
作者:  
Lin G.-Y.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
Tandem gratings of double-dispersion mount make it possible to design an imaging spectrometer for the weak light observation with high spatial resolution  high spectral resolution  and high optical transmission efficiency. The traditional tandem Wadsworth mounting is originally designed to match the coaxial telescope and large-scale imaging spectrometer. When it is used to connect the off-axis telescope such as off-axis parabolic mirror  it presents lower imaging quality than to connect the coaxial telescope. It may also introduce interference among the detector and the optical elements as it is applied to the short focal length and small-scale spectrometer in a close volume by satellite. An advanced tandem Wadsworth mounting has been investigated to deal with the situation. The Wadsworth astigmatism-corrected mounting condition for which is expressed as the distance between the second concave grating and the imaging plane is calculated. Then the optimum arrangement for the first plane grating and the second concave grating  which make the anterior Wadsworth condition fulfilling each wavelength  is analyzed by the geometric and first order differential calculation. These two arrangements comprise the advanced Wadsworth mounting condition. The spectral resolution has also been calculated by these conditions. An example designed by the optimum theory proves that the advanced tandem Wadsworth mounting performs excellently in spectral broadband. 2012 Optical Society of America.  
Design of the real-time autofocusing system for collimator with long focus length and large aperture (EI CONFERENCE) 会议论文  OAI收割
2011 International Academic Conference on Numbers, Intelligence, Manufacturing Technology and Machinery Automation, MAMT 2011, December 24, 2011 - December 25, 2011, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
Large aperture collimator which has been widely used for calibrating and testing various optical devices plays an essential role in correlative laboratories. As being the basic testing and calibration equipment  the large aperture collimator's accuracy should be much higher than the device under testing in order to ensure the accuracy of the measurement. However  the process of adjusting the collimator is extremely complicated due to the collimator's large aperture and long focal length. So it is difficult to ensure the measurement's quality and easy to cause the system being vulnerable to the surrounding environment. One of the most common problems is defocus. In order to solve the problem above  this issue presents a new type of autocollimator autofocusing system which uses pentaprism instead of using large-aperture plane mirror  semiconductor lasers as light source and CCD sensor as receiver. The system is smaller  lighter  and more convenient when using. The computer simulation shows that the autofocusing system's resolution could reach the accuracy of 40m. If we use the relevant algorithms to execute the sub-pixel scanning  the resolution could reach the accuracy of 10m. It shows that the system could satisfy the required testing precision of testing large aperture optical device.  
Study on ultra-light secondary baffle for coaxial two-mirror telescope (EI CONFERENCE) 会议论文  OAI收割
2012 9th IEEE International Conference on Mechatronics and Automation, ICMA 2012, August 5, 2012 - August 8, 2012, Chengdu, China
作者:  
Zhang L.;  Zhang L.
收藏  |  浏览/下载:44/0  |  提交时间:2013/03/25
The coaxial two-mirror telescope consists of two mirrors facing each other. Classical two-mirror arrangements are Gregorian and Cassegrain. These systems are usually applied to space telescopes and often have optical baffles to prevent stray light from entering the focal plane. The optical baffles consist of concentric rings suspended between the secondary and the primary mirror. The secondary baffle for a large two-mirror optical system is designed and analyzed in this paper. According to mission of a telescope  the structure should have high stiffness and high reliability and light weight. Compared with invar  aluminum alloy and titanium alloy  carbon fiber composite is currently the best material in terms of weight-to-strength ratio. It also has advantages of high temperature tolerance and low thermal expansion. So carbon fiber composite is chosen as material to meet requirements of the coaxial telescope. In this paper  optimization method based on finite element analysis (FEA) is used for design the secondary baffle. Minimum weight of the baffle is chosen as an objective function. Thicknesses of former tube and vanes are chosen as variables. Analysis results show that the designed secondary baffle has maximum diameter of 180mm  total length of 120mm and weighs 142g. And its fundamental frequency reaches 651Hz. Therefore the baffle has many advantages  such as ultra-light weight  high stiffness and dimensional stability  etc. The optimization method and the baffle design can be helpful to other coaxial telescopes  such as Cassegrain  Gregorian and their subdivisions. 2012 IEEE.  
Simulation test research of using the Ritchey-Common method for the detection of large flat mirror (EI CONFERENCE) 会议论文  OAI收割
2012 International Conference on Frontiers of Advanced Materials and Engineering Technology, FAMET 2012, January 4, 2012 - January 5, 2012, Xiamen, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:11/0  |  提交时间:2013/03/25
A method on improvement of wavelength resolution of grating spectrometers 会议论文  OAI收割
IET International Conference on Communication Technology and Application, ICCTA 2011, Beijing, China, October 14, 2011 - October 16, 2011
作者:  
Song JH;  Yang QS(杨乾锁);  Zou NY
收藏  |  浏览/下载:11/0  |  提交时间:2017/06/20
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:  
Wang S.-R.;  Lin G.-Y.;  Yu L.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding  the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror  a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror  coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected  and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system  a deuterium lamp  a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.  
The reflector bracket mirror structure optimization and design of the IR warring system (EI CONFERENCE) 会议论文  OAI收割
2011 International Conference on Advanced Engineering Materials and Technology, AEMT 2011, July 29, 2011 - July 31, 2011, Sanya, China
作者:  
Wang B.;  Wang B.
收藏  |  浏览/下载:15/0  |  提交时间:2013/03/25
This paper introduced a kind of reflector mirror support structure of IRST system. Thescanning reflector mirror support frame material is Ly2 aluminum under the principle of the suited ofmaterial expanding quotient. The support form of the reflector was talked  and the system bracketstructure was designed following the requests of the certain complex IRST. The bracket wasoptimized and analyzed under the best structure quality and the least moment of inertia  and thebellowing of bracket plane thickness  mode frequency restriction and deadweight restriction. Fromthe result we can see that the bracket mass can reduce from 0.73kg to 0.49kg and the moment ofinertia can reduce from 0.0109kg2 to 0.0056 kg2 under the first precondition of the structure modefrequency being low and the biggest transmogrification being teeny. The base frequency and intensionof the complex IRST system can be indicated well after the finite element analysis static checking. (2011) Trans Tech Publications  Switzerland.