中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Global calibration of multi-cameras with non-overlapping fields of view based on photogrammetry and reconfigurable target

文献类型:期刊论文

作者Hu MB(胡茂邦)1,2; Xia RB(夏仁波)2; Chen YL(陈月玲)2; Chen SL(陈松林)1,2; Zhao JB(赵吉宾)2
刊名MEASUREMENT SCIENCE AND TECHNOLOGY
出版日期2018
卷号29期号:6页码:1-10
ISSN号0957-0233
关键词Global Calibration Photogrammetry Non-overlapping Fields Of View Reconfigurable Targets
产权排序1
英文摘要

Multi-camera vision systems are often needed to achieve large-scale and high-precision measurement because these systems have larger fields of view (FOV) than a single camera. Multiple cameras may have no or narrow overlapping FOVs in many applications, which pose a huge challenge to global calibration. This paper presents a global calibration method for multi-cameras without overlapping FOVs based on photogrammetry technology and a reconfigurable target. Firstly, two planar targets are fixed together and made into a long target according to the distance between the two cameras to be calibrated. The relative positions of the two planar targets can be obtained by photogrammetric methods and used as invariant constraints in global calibration. Then, the reprojection errors of target feature points in the two cameras' coordinate systems are calculated at the same time and optimized by the Levenberg-Marquardt algorithm to find the optimal solution of the transformation matrix between the two cameras. Finally, all the camera coordinate systems are converted to the reference coordinate system in order to achieve global calibration. Experiments show that the proposed method has the advantages of high accuracy (the RMS error is 0.04mm) and low cost and is especially suitable for on-site calibration.

WOS关键词EXTERNAL PARAMETER CALIBRATION ; MIRROR
资助项目National Natural Science Foundation of the People's Republic of China[51375476]
WOS研究方向Engineering ; Instruments & Instrumentation
语种英语
WOS记录号WOS:000430345500001
资助机构National Natural Science Foundation of the People's Republic of China
源URL[http://119.78.100.139/handle/173321/21852]  
专题沈阳自动化研究所_装备制造技术研究室
通讯作者Xia RB(夏仁波)
作者单位1.University of Chinese Academy of Sciences, Beijing, China
2.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China;
推荐引用方式
GB/T 7714
Hu MB,Xia RB,Chen YL,et al. Global calibration of multi-cameras with non-overlapping fields of view based on photogrammetry and reconfigurable target[J]. MEASUREMENT SCIENCE AND TECHNOLOGY,2018,29(6):1-10.
APA Hu MB,Xia RB,Chen YL,Chen SL,&Zhao JB.(2018).Global calibration of multi-cameras with non-overlapping fields of view based on photogrammetry and reconfigurable target.MEASUREMENT SCIENCE AND TECHNOLOGY,29(6),1-10.
MLA Hu MB,et al."Global calibration of multi-cameras with non-overlapping fields of view based on photogrammetry and reconfigurable target".MEASUREMENT SCIENCE AND TECHNOLOGY 29.6(2018):1-10.

入库方式: OAI收割

来源:沈阳自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。