中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共4条,第1-4条 帮助

条数/页: 排序方式:
OS-DS tracker: Orientation-variant Siamese 3D tracking with Detection based Sampling 期刊论文  OAI收割
PATTERN RECOGNITION LETTERS, 2023, 卷号: 174, 页码: 7
作者:  
Zhang, Qiuyu;  Wang, Lipeng;  Li, Wanyi;  Meng, Hao;  Zhang, Wen
  |  收藏  |  浏览/下载:21/0  |  提交时间:2023/11/16
自动进样系统结合电化学法检测河水中总铁 期刊论文  OAI收割
环境化学, 2019, 卷号: 38, 期号: 10, 页码: 2229-2236
作者:  
潘飞;  潘大为;  韩海涛;  王晨晨
  |  收藏  |  浏览/下载:14/0  |  提交时间:2020/07/08
An auto-focus algorithm of fast search based on combining rough and fine adjustment (EI CONFERENCE) 会议论文  OAI收割
3rd international Conference on Manufacturing Science and Engineering, ICMSE 2012, March 27, 2012 - March 29, 2012, Xiamen, China
作者:  
Zhang S.;  Zhang Y.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
A coarse and fine combined fast search and auto-focusing algorithm was suggested in this paper. This method can automatically search and find the focal plane by evaluating the image definition. The Krisch operator based edge energy function was used as the big-step coarse focusing  and then the wavelet transform based image definition evaluation function  which is sensitivity to the variation in image definition  was used to realize the small-step fine focusing in a narrow range. The un-uniform sampling function of the focusing area selection used in this method greatly reduces the workload and the required time for the data processing. The experimental results indicate that this algorithm can satisfy the requirement of the optical measure equipment for the image focusing. (2012) Trans Tech Publications.  
Research on automatic Hartmann test of membrane mirror (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang P.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
Electrostatic membrane mirror is ultra-lightweight and easy to acquire a large diameter comparing with traditional optical elements  so its development and usage is the trend of future large mirrors. In order to research the control method of the static stretching membrane mirror  the surface configuration must be tested. However  membrane mirror's shape is always changed by variable voltages on the electrodes  and the optical properties of membrane materials using in our experiment are poor  so it is difficult to test membrane mirror by interferometer and null compensator method. To solve this problem  an automatic optical test procedure for membrane mirror is designed based on Hartmann screen method. The optical path includes point light source  CCD camera  splitter and diffuse transmittance screen. The spots' positions on the diffuse transmittance screen are pictured by CCD camera connected with computer  and image segmentation and centroid solving is auto processed. The CCD camera's lens distortion is measured  and fixing coefficients are given to eliminate the spots' positions recording error caused by lens distortion. To process the low sampling Hartmann test results  Zernike polynomial fitting method is applied to smooth the wave front. So low frequency error of the membrane mirror can be measured then. Errors affecting the test accuracy are also analyzed in this paper. The method proposed in this paper provides a reference for surface shape detection in membrane mirror research. 2010 Copyright SPIE - The International Society for Optical Engineering.