中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
上海应用物理研究所 [1]
近代物理研究所 [1]
采集方式
OAI收割 [4]
内容类型
会议论文 [2]
期刊论文 [2]
发表日期
2021 [1]
2010 [2]
2009 [1]
学科主题
Nuclear Sc... [1]
筛选
浏览/检索结果:
共4条,第1-4条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
2 K cryogenic system development for superconducting cavity testing of CiADS
期刊论文
OAI收割
CRYOGENICS, 2021, 卷号: 115, 页码: 13
作者:
Xiao-fei, Niu
;
Feng, Bai
;
Xian-jin, Wang
;
Peng, Zhang
;
Yong-hui, Yang
  |  
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2021/12/10
CiADS
Superconducting
Cryogenic system
Liquid helium
2 K
Cavity testing
Temperature gradients effect on surface test with high precise interferometer (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Gu Y.-Q.
;
Yang H.-J.
;
Sui Y.-X.
;
Zhang J.
;
Zhang J.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
In high precise surface testing
temperature stability and uniformity are of paramount importance to the high accuracy of test results. Micro-temperature variation and temperature gradients not only cause the change of the air refractive index and lead to the optical path variation in interferometer cavity
but also result in deformation of the tested surface itself
which always brings about errors to the test results. Temperature effects on the interferometer cavity and the tested surface are analyzed from the axial and radial directions in this letter. Temperature model of the interferometer cavity and the tested lens are established and quantitative calculations and diagram of test results versus temperature and lens dimension are provided. It shows that temperature gradients effect increase with the length of the interferometer and the dimension of the tested lens. The interferometer cavity is mainly affected by radial temperature gradients while the tested lens is mainly affected by the axial temperature gradients. 2010 Copyright SPIE - The International Society for Optical Engineering.
Influence of spatial temperature distribution on high accuracy interferometric metrology (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Yang H.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Yan F.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
We calculate the influence of temperature change on the refractive index of air
establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First
a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air
followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer
accompanied by a temperature change random function within each grid. Finally
all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position
angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result
the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus
to realize the high accuracy figure metrology
the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer. 2010 Copyright SPIE - The International Society for Optical Engineering.
Evaluation of external quality factor of the superconducting cavity using extrapolation method
期刊论文
OAI收割
NUCLEAR SCIENCE AND TECHNIQUES, 2009, 卷号: 20, 期号: 2, 页码: 6
Ma, ZY(马震宇)
;
Ma, GM
;
Hou, HT(侯洪涛)
;
Yu, HB
;
Zhang, R
;
Liu, JF(刘剑飞)
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2012/04/11
External quality factor
Vertical testing
Superconducting cavity
Coaxial input coupler