中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共6条,第1-6条 帮助

条数/页: 排序方式:
Analysis of assembly errors of optomechanical systems 会议论文  OAI收割
Shenzhen, China, 2023-08-04
作者:  
Chou, Xiaoquan;  Li, Zhiguo;  Li, Xiaoyan
  |  收藏  |  浏览/下载:5/0  |  提交时间:2024/02/28
Evaluation of sulfur trioxide detection with online isopropanol absorption method 期刊论文  OAI收割
JOURNAL OF ENVIRONMENTAL SCIENCES, 2018, 卷号: 72, 页码: 25-32
作者:  
Xiong, Jin;  Li, Yuran;  Wang, Jian;  Yang, Yang;  Zhu, Tingyu
  |  收藏  |  浏览/下载:62/0  |  提交时间:2018/12/04
Geocentric distance's errors' correction of space cameras based on USGS DEM (EI CONFERENCE) 会议论文  OAI收割
2011 IEEE 3rd International Conference on Communication Software and Networks, ICCSN 2011, May 27, 2011 - May 29, 2011, Xi'an, China
作者:  
Li W.;  Li W.;  Xu S.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
In order to correct the geocentric distance's error of TDI (Time Delay and Integration) CCD space camera in calculation of image motion compensation  the data source of the earth's height above sea level USGS DEM (United States Geological Survey Digital Elevation Model) has been introduced to make digital elevation map  the match error of the forward direction (the integral direction of TDI CCD) has been greatly decreased by correcting the geocentric distance error  and eliminate the influence to the relative error of image motion velocity  and correct the error generated by the different heights above sea level. After correcting  which greatly improves the imaging quality of TDI CCD space camera. 2011 IEEE.  a model of image motion calculation of nadir has been introduced  the calculation and analysis of the model shows that: the maximum error of image motion velocity about 1.72% has been decreased to 0.06%  and the influence of the geocentric distance error to the relative error of image motion velocity has been analyzed with the model  
Analysis of measuring errors for the visible light phase-shifting point diffraction interferometer (EI CONFERENCE) 会议论文  OAI收割
2010 OSA-IEEE-COS Advances in Optoelectronics and Micro/Nano-Optics, AOM 2010, December 3, 2010 - December 6, 2010, Guangzhou, China
作者:  
Zhang Y.
收藏  |  浏览/下载:13/0  |  提交时间:2013/03/25
In order to improve the measuring accuracy of the visible light phase-shifting point diffraction interferometer (PS/PDI) for the extreme ultraviolet lithography (EUVL) aspheric mirrors  the main measuring errors will be discussed in this paper. At first  the elementary configuration and measuring principle of the visible light phase-shifting point diffraction interferometer are introduced briefly  then the different errors which are possible to affect the measuring result are summed up  the errors include PZT phase-shifting error  detector nonlinearity error  detector quantization error  wavelength instability error and intensity instability error of the laser source  vibration error  air refractivity instability error and so on. Through detailed analysis and simulation  the magnitude of these errors can be obtained. By analysing the reasons which cause these errors and the relationship between these errors and interferometer configuration parameters  some methods are put forward to avoid or restrain these errors accordingly.  
Design of a scene simulator in land-based aerospace lab with the man-made light source system based on quantum theory (EI CONFERENCE) 会议论文  OAI收割
Optoelectronic Devices and Integration II, November 12, 2007 - November 15, 2007, Beijing, China
作者:  
Fang W.;  Yi W.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
The paper presents a method with the technique of combination filtering of spectrum and the technique of DSP control for the simulation and recognition of the spontaneously lightening object and stellar map in the universe. The magnitude and the spectrum of a star can be simulated in a wide dynamic range. We established the mathematical models of the Vega's visible light spectrum and luminous flux density. Tungsten-halogen lamp as a light source is used to fit the linear light of the spontaneously lightening object in the universe. Through the experiment  it shows that the more sub-channels there are while filtering spectrum in the visible spectrum  and the more degrees the variable neutral density filters and the narrow-band attenuators have  more close to the actual spectrum the simulated spectrum is. It is proved that using the PID technique is beneficial to the output of the accurate and steady radiation from the light sources. The experiment shows that the using of this method can get perfect result in fitting and simulating the spectrum  magnitude and the stellar map of the spontaneously lightening object . The analysis of the consistent result and the experimental error is also discussed in detail in this paper.  
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.; Li H.; Chen C.; Zhou C.; Qian S.
收藏  |  浏览/下载:35/0  |  提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal  spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle  optical system  mechanical constructions  DC serve motor control system  array detector  data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy  low cost  multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.