中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共8条,第1-8条 帮助

条数/页: 排序方式:
A numerical comparison between internal cooling and side cooling of the reflection mirror for Spatial and Spin (S-2) beam-line at SSRF 期刊论文  OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 卷号: 902, 期号: -, 页码: 190-196
作者:  
Jin, LM;  Zhu, WQ
  |  收藏  |  浏览/下载:17/0  |  提交时间:2019/12/17
Development of fundamental power coupler for c-ads superconducting elliptical cavities 期刊论文  iSwitch采集
Chinese physics c, 2017, 卷号: 41, 期号: 6, 页码: 6
作者:  
Gu, Kui-Xiang
收藏  |  浏览/下载:32/0  |  提交时间:2019/04/23
Development of fundamental power coupler for C-ADS superconducting elliptical cavities 期刊论文  OAI收割
CHINESE PHYSICS C中国物理. C, 2017, 卷号: 41, 期号: 6, 页码: 67001
作者:  
Meng FB(孟繁博);  Gu KX(谷魁祥);  Bing F(邴丰);  Pan WM(潘卫民);  Huang TM(黄彤明)
  |  收藏  |  浏览/下载:30/0  |  提交时间:2019/08/27
FEA-based structural optimization design of a side cooling collimating mirror at SSRF 期刊论文  OAI收割
NUCLEAR SCIENCE AND TECHNIQUES, 2017, 卷号: 28, 期号: 11, 页码: -
作者:  
Jin, LM;  Wang, NX;  Zhu, WQ;  Bian, FG
  |  收藏  |  浏览/下载:26/0  |  提交时间:2018/08/30
Monochromatic x-ray-induced thermal effect on four-reflection "nested" mev-monochromators: dynamical diffraction theory and finite-element analysis 期刊论文  iSwitch采集
Chinese physics c, 2015, 卷号: 39, 期号: 9, 页码: 7
作者:  
Hu Ling-Fei;  Gao Li-Dan;  Li Zhen-Jie;  Wang Shan-Feng;  Sheng Wei-Fan
收藏  |  浏览/下载:29/0  |  提交时间:2019/04/23
Monochromatic X-ray-induced thermal effect on four-reflection "nested" meV-monochromators: dynamical diffraction theory and finite-element analysis 期刊论文  OAI收割
CHINESE PHYSICS C, 2015, 卷号: 39, 期号: 9, 页码: 96004
作者:  
Hu LF(胡凌飞);  Gao LD(高立丹);  Li ZJ(李贞杰);  Wang SF(王山峰);  Sheng WF(盛伟繁)
收藏  |  浏览/下载:41/0  |  提交时间:2016/04/18
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.; Li H.; Chen C.; Zhou C.; Qian S.
收藏  |  浏览/下载:35/0  |  提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal  spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle  optical system  mechanical constructions  DC serve motor control system  array detector  data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy  low cost  multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.