中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [9]
光电技术研究所 [1]
采集方式
OAI收割 [10]
内容类型
会议论文 [8]
期刊论文 [2]
发表日期
2018 [1]
2016 [1]
2012 [1]
2011 [1]
2010 [2]
2009 [2]
更多
学科主题
筛选
浏览/检索结果:
共10条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
作者升序
作者降序
Indirect validation method of thermal design for exposed opto-electro-mechanical instrument on satellite
期刊论文
OAI收割
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2018, 卷号: 26, 期号: 7, 页码: 1741-1748
作者:
Liu, Shao-Ran
;
Liu, Bai-Lin
;
Luo, Zhi-Tao
;
Yang, Qing-Bo
  |  
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2019/09/17
Optical communication
Communication satellites
Instrument testing
Orbits
Satellites
Test facilities
Analysis of offset error for segmented micro-structure optical element based on optical diffraction theory
期刊论文
OAI收割
Proceedings of SPIE: 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, 2016, 卷号: 9682, 页码: 968210
作者:
Su, Jinyan
;
Wu, Shibin
;
Yang, Wei
;
Wang, Lihua
  |  
收藏
  |  
浏览/下载:59/0
  |  
提交时间:2018/06/14
Diffraction
Errors
Functions
Image Quality
Lenses
Manufacture
Microstructure
Mirrors
Optical Instrument Lenses
Optical Systems
Optical Testing
Telescopes
The research of round raster readheads scheme (EI CONFERENCE)
会议论文
OAI收割
3rd international Conference on Manufacturing Science and Engineering, ICMSE 2012, March 27, 2012 - March 29, 2012, Xiamen, China
Cong J.-F.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
The round raster is extensively applied in all kinds of high accuracy angular displacement measurement and control system. With the development of precise mechanotronics measuring instrument
machining center
CNC machine and various precise location testing technology
a higher request is put forward to the accuracy and the function of raster measurement system. In this article it is concluded that double readheads is the most reasonable configuration scheme through tests of single readhead scheme
two readheads and four readheads. (2012) Trans Tech Publications.
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
Design of co-path scanning long trace profiler for measurement of X-ray space optical elements (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Shun L.
;
Yan G.
;
Wei Z.
;
Yang Z.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
The Long Trace Profiler (LTP) is a precision surface slope error measurement instrument used in synchrotron radiation optics for many years. By making some modifications to the LTP system
we developed a co-path scanning LTP (CSLTP) system to test the cylindrical aspherical surface which used in X-ray space optics. To reduce the mistake caused by air turbulence and manufacture faults of optical elements used
the CSLTP is designed with the least difference between the testing beam path and the reference beam path. Also
it uses multiple-beam interference but double beam interference to reduce the width of beam fringe. This improves the position precision of the beam fringe on the image plane. 2010 SPIE.
Small aircraft CAN bus signal acquisition equipment (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Chen C.-Q.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
Small aircraft often used RS485 bus. But with the complexity of the small aircraft's subsystems increase and the progress of field bus technology
CAN bus systems in small aircraft use more and more widely. How to record real-time flight experiment data on the small aircraft's CAN bus and provide test data for reproducing the process of a small aircraft flying is very important. This paper presents a design method of signal acquisition device
it can be used for small aircraft flying field experiment. 2010 IEEE.
as the main chip with DSP2812
SJA1000 as CAN controller
CTM1050 as the CAN transceiver
CF card as storage media. Gives the diagram of its hardware and software design process. Combined with the background of a small aircraft
testing the instrument for data acquisition when the ground experiments and flight progress. Experimental data show that the design of high reliability and CAN signals can effectively complete the record
A TDI CCD simulation instrument (EI CONFERENCE)
会议论文
OAI收割
2009 IEEE International Conference on Mechatronics and Automation, ICMA 2009, August 9, 2009 - August 12, 2009, Changchun, China
作者:
Liu H.
;
Li Y.
;
Li Y.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
TDI CCD is widely used in the high speed imaging camera
glimmering vision and robotic vision fields
because of its excellent operation. But TDI CCD's high ordering price and easy damage in circuit testing usually limit its application in real projects. In this paper basing the simulation of both the photoelectronic character and electronic character
a instrument is described in details. 2009 IEEE.
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:
Song K.-F.
;
Li J.-L.
;
Zhang W.-L.
;
Wang Y.-L.
收藏
  |  
浏览/下载:40/0
  |  
提交时间:2013/03/25
In the device
a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source
and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system
so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least
the sample fluorescence through the integrating sphere and come to the grating monochromator
The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device
SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process
signal-to-noise ratio(SNR) will be improved
also adjust delay time
ampling frequency and sampling number arbitrarily. By testing
the sensitivity is 10-12mol/L(substance marked by Eu3+)
examination repeat is &le2.5%
examination linearity is from 10 -8mol/L to 10-12mol/L
correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody
and solve the tumor
genetic variation
the virus protein detection. 2009 SPIE.
Research on the airborne communication and navigation apparatus ATE system based on the virtual instrument (EI CONFERENCE)
会议论文
OAI收割
2008 Pacific-Asia Workshop on Computational Intelligence and Industrial Application, PACIIA 2008, December 19, 2008 - December 20, 2008, Wuhan, China
Zijing Z.
;
Zhongbao X.
;
Yanbin S.
收藏
  |  
浏览/下载:77/0
  |  
提交时间:2013/03/25
The airborne communication and navigation (CN) apparatus ATE system is the important apparatus for measure the working state and performance of the CN automatically and quickly. It has explained the composition of the ATE system based on the virtual instrument
the bus structure and signal recuperated in this paper. The ATE System adopts platformization fault diagnosis thought
the fault diagnose mechanism and logic are designed by the users
which is an organic whole realized the fault diagnoses and the maintain means coordination. System is interchangeable and upgradeable on operating system
special-purpose tester
and the testing program is portable between the different ATE. Indicate by the practice
the airborne CN apparatus ATE system have good military and economic benefits. 2008 IEEE.
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.
;
Li H.
;
Chen C.
;
Zhou C.
;
Qian S.
收藏
  |  
浏览/下载:42/0
  |  
提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal
spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle
optical system
mechanical constructions
DC serve motor control system
array detector
data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy
low cost
multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.