中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共10条,第1-10条 帮助

条数/页: 排序方式:
Indirect validation method of thermal design for exposed opto-electro-mechanical instrument on satellite 期刊论文  OAI收割
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2018, 卷号: 26, 期号: 7, 页码: 1741-1748
作者:  
Liu, Shao-Ran;  Liu, Bai-Lin;  Luo, Zhi-Tao;  Yang, Qing-Bo
  |  收藏  |  浏览/下载:24/0  |  提交时间:2019/09/17
Analysis of offset error for segmented micro-structure optical element based on optical diffraction theory 期刊论文  OAI收割
Proceedings of SPIE: 8th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, 2016, 卷号: 9682, 页码: 968210
作者:  
Su, Jinyan;  Wu, Shibin;  Yang, Wei;  Wang, Lihua
  |  收藏  |  浏览/下载:59/0  |  提交时间:2018/06/14
The research of round raster readheads scheme (EI CONFERENCE) 会议论文  OAI收割
3rd international Conference on Manufacturing Science and Engineering, ICMSE 2012, March 27, 2012 - March 29, 2012, Xiamen, China
Cong J.-F.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:  
Wang S.-R.;  Lin G.-Y.;  Yu L.
收藏  |  浏览/下载:39/0  |  提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding  the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror  a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror  coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected  and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system  a deuterium lamp  a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.  
Design of co-path scanning long trace profiler for measurement of X-ray space optical elements (EI CONFERENCE) 会议论文  OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Shun L.; Yan G.; Wei Z.; Yang Z.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
Small aircraft CAN bus signal acquisition equipment (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Chen C.-Q.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
Small aircraft often used RS485 bus. But with the complexity of the small aircraft's subsystems increase and the progress of field bus technology  CAN bus systems in small aircraft use more and more widely. How to record real-time flight experiment data on the small aircraft's CAN bus and provide test data for reproducing the process of a small aircraft flying is very important. This paper presents a design method of signal acquisition device  it can be used for small aircraft flying field experiment. 2010 IEEE.  as the main chip with DSP2812  SJA1000 as CAN controller  CTM1050 as the CAN transceiver  CF card as storage media. Gives the diagram of its hardware and software design process. Combined with the background of a small aircraft  testing the instrument for data acquisition when the ground experiments and flight progress. Experimental data show that the design of high reliability and CAN signals can effectively complete the record  
A TDI CCD simulation instrument (EI CONFERENCE) 会议论文  OAI收割
2009 IEEE International Conference on Mechatronics and Automation, ICMA 2009, August 9, 2009 - August 12, 2009, Changchun, China
作者:  
Liu H.;  Li Y.;  Li Y.;  Li Y.;  Li Y.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Song K.-F.;  Li J.-L.;  Zhang W.-L.;  Wang Y.-L.
收藏  |  浏览/下载:40/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.  
Research on the airborne communication and navigation apparatus ATE system based on the virtual instrument (EI CONFERENCE) 会议论文  OAI收割
2008 Pacific-Asia Workshop on Computational Intelligence and Industrial Application, PACIIA 2008, December 19, 2008 - December 20, 2008, Wuhan, China
Zijing Z.; Zhongbao X.; Yanbin S.
收藏  |  浏览/下载:77/0  |  提交时间:2013/03/25
The airborne communication and navigation (CN) apparatus ATE system is the important apparatus for measure the working state and performance of the CN automatically and quickly. It has explained the composition of the ATE system based on the virtual instrument  the bus structure and signal recuperated in this paper. The ATE System adopts platformization fault diagnosis thought  the fault diagnose mechanism and logic are designed by the users  which is an organic whole realized the fault diagnoses and the maintain means coordination. System is interchangeable and upgradeable on operating system  special-purpose tester  and the testing program is portable between the different ATE. Indicate by the practice  the airborne CN apparatus ATE system have good military and economic benefits. 2008 IEEE.  
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE) 会议论文  OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.; Li H.; Chen C.; Zhou C.; Qian S.
收藏  |  浏览/下载:42/0  |  提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal  spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle  optical system  mechanical constructions  DC serve motor control system  array detector  data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy  low cost  multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.