中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
高能物理研究所 [3]
长春光学精密机械与物... [1]
近代物理研究所 [1]
采集方式
OAI收割 [4]
iSwitch采集 [1]
内容类型
期刊论文 [4]
会议论文 [1]
发表日期
2020 [1]
2016 [1]
2008 [2]
2003 [1]
学科主题
Instrument... [1]
筛选
浏览/检索结果:
共5条,第1-5条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Constraining the X-Ray-Infrared Spectral Index of Second-timescale Flares from SGR 1935+2154 with Palomar Gattini-IR
期刊论文
OAI收割
The Astrophysical Journal, 2020, 卷号: 901, 页码: L7
作者:
HXMT
  |  
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2022/02/08
Radio transient sources
Magnetars
Soft gamma-ray repeaters
2008
992
1471
Astrophysics - High Energy Astrophysical Phenomena
Astrophysics - Instrumentation and Methods for Astrophysics
Abstract: The Galactic magnetar SGR 1935+2154 has been reported to produce the first example of a bright millisecond-duration radio burst (FRB 200428) similar to the cosmological population of fast radio bursts (FRBs). The detection of a coincident bright X-ray burst represents the first observed multiwavelength counterpart of an FRB. However, the search for similar emission at optical wavelengths has been hampered by the high inferred extinction on the line of sight. Here, we present results from the first search for second-timescale emission from the source at near-infrared (NIR) wavelengths using the Palomar Gattini-IR observing system in the J band, enabled by a novel detector readout mode that allows short exposure times of ?0.84 s with 99.9% observing efficiency. With a total observing time of ?12 hr (?47,728 images) during its 2020 outburst, we place median 3Ҡlimits on the second-timescale NIR fluence of ?18 Jy ms (13.1 AB mag). The corresponding extinction-corrected limit is ?125 Jy ms for an estimated extinction of A
J
= 2.0 mag. Our observations were sensitive enough to easily detect an NIR counterpart of FRB 200428 if the NIR emission falls on the same power law as observed across its radio to X-ray spectrum. We report nondetection limits from epochs of four simultaneous X-ray bursts detected by the Insight-HXMT and NuSTAR telescopes during our observations. These limits provide the most stringent constraints to date on fluence of flares at 10
14
Hz, and constrain the fluence ratio of the NIR emission to coincident X-ray bursts to R
NIR
? 0.025 (fluence index ?0.35).
Peptidic beta-sheet binding with congo red allows both reduction of error variance and signal amplification for immunoassays
期刊论文
iSwitch采集
Biosensors & bioelectronics, 2016, 卷号: 86, 页码: 211-218
作者:
Wang, Yunyun
;
Liu, Ye
;
Deng, Xinli
;
Cong, Yulong
;
Jiang, Xingyu
收藏
  |  
浏览/下载:134/0
  |  
提交时间:2019/04/23
Peptidic beta-sheet
Congo red
P-selectin
Readout mode
Immunoassays
Driving techniques for high frame rate CCD camera (EI CONFERENCE)
会议论文
OAI收割
Electronic Imaging and Multimedia Technology V, November 12, 2007 - November 15, 2007, Beijing, China
Guo W.
;
Jin L.
;
Xiong J.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
This paper describes a high-frame rate CCD camera capable of operating at 100 frames/s. This camera utilizes Kodak KAI-0340
an interline transfer CCD with 640(vertical)480(horizontal) pixels. Two output ports are used to read out CCD data and pixel rates approaching 30 MHz. Because of its reduced effective opacity of vertical charge transfer registers
interline transfer CCD can cause undesired image artifacts
such as random white spots and smear generated in the registers. To increase frame rate
a kind of speed-up structure has been incorporated inside KAI-0340
then it is vulnerable to a vertical stripe effect. The phenomena which mentioned above may severely impair the image quality. To solve these problems
some electronic methods of eliminating these artifacts are adopted. Special clocking mode can dump the unwanted charge quickly
then the fast readout of the images
cleared of smear
follows immediately. Amplifier is used to sense and correct delay mismatch between the dual phase vertical clock pulses
the transition edges become close to coincident
so vertical stripes disappear. Results obtained with the CCD camera are shown.
Testing the absolute beam intensity of the high-energy pulsed electron beam with a double-mode readout ionization chamber
期刊论文
OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 卷号: 592, 期号: 3, 页码: 498-501
作者:
Gou QB(苟全补)
;
Feng CY(冯朝阳)
;
Shi F(石峰)
;
Liao JY(廖进元)
;
Gou, Q
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2016/06/28
ionization chamber
double-mode readout
high-energy pulsed electron beam
Development of low pressure position sensitive multiwire proportional chamber
期刊论文
OAI收割
HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 卷号: 27, 页码: 1023-1026
作者:
Zhang, BG
;
Wen, WX
;
Wei, ZY
;
Zhang, JX
;
Feng, Y
  |  
收藏
  |  
浏览/下载:16/0
  |  
提交时间:2018/05/31
low pressure multiwire proportional chamber
position resolution
delay line readout mode
position determination efficiency