中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共4条,第1-4条 帮助

条数/页: 排序方式:
Response spectrum 0.9-2.65 m of In0.82Ga0.18As detectors by two-step growth technique (EI CONFERENCE) 会议论文  OAI收割
2012 International Conference on Material Sciences and Manufacturing Technology, ICMSMT 2012, October 5, 2012 - October 6, 2012, Dalian, China
作者:  
Zhang T.
收藏  |  浏览/下载:46/0  |  提交时间:2013/03/25
InP/In0.82Ga0.18As/InP heterostructure used for infrared detector were grown on (100) S-doped InP substrates using two-step growth technique by low temperature metal-organic chemical vapor deposition. The growth was performed using TMIn  TMGa  AsH3  and PH3 as growth precursors in a horizontal reactor. The substrates on a graphite susceptor were heated by inductively coupling RF power  their temperatures were detected by a thermocouple  and the reactor pressure was kept at 10000 Pa. The growth structure of detector included In0.82Ga0.18As buffer with the thickness of 100 nm  In0.82Ga0.18As absorption layer with the thickness of 2.8 m  and the InP cap with the thickness of 0.8 m. The planar type of p-i-n detector was fabricated by Zn diffusion. The properties of In0.82Ga0.18As detector were studied  the curves of the I-V characteristics  the range of response spectrum  and the detectivity (D*) were obtained. (2013) Trans Tech Publications  Switzerland.  
Experimental and theoretical investigation of environmental media on very-high-cycle fatigue behavior for a structural steel 期刊论文  OAI收割
Acta Materialia, 2011, 卷号: 59, 期号: 4, 页码: 1321-1327
作者:  
Qian GA(钱桂安);  Zhou CE(周承恩);  Hong YS(洪友士)
收藏  |  浏览/下载:25/0  |  提交时间:2012/04/01
Noise processing technology of a TDICCD sensor (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
作者:  
Zhang L.-P.
收藏  |  浏览/下载:21/0  |  提交时间:2013/03/25
In the application of TDI-CCD  the other is all kinds of interference noise produced in the working process of a TDI-CCD  for reset noise  because of its serious noise interference  such as reset noise and 1 / f noise  correlated double sampling is employed. The experimental results show that after noise processing  the imaging quality is reduced  etc. According to the features of noise  the output S/N has been raised to about 50 dB. 2010 IEEE.  so that it is necessary to study the noise characteristics of TDI-CCD. There are two categories of noise  this paper has studied the corresponding noise-processing technology. For dark current noise  one is the inherent noise  refrigeration is taken  including shot noise  dark current noise  fixed pattern noise and transfer noise etc.  
Design and analysis of power system of micro-electromechanical actuator (EI CONFERENCE) 会议论文  OAI收割
2010 2nd International Conference on Industrial Mechatronics and Automation, ICIMA 2010, May 30, 2010 - May 31, 2010, Wuhan, China
作者:  
Zhang J.;  Zhang J.;  Zhang J.
收藏  |  浏览/下载:30/0  |  提交时间:2013/03/25
In order to apply the electromechanical actuator to tactical mini-missiles  maximum rotational speed of output shafts is greater than 250/s. Test results basically correspond to the requirement of technical indexes. It is proved that this analysis and design method is congruent with the design of micro-electromechanical actuators  this paper researches on the key technology such as load-bearing ability  the system bandwidth can reach 25.3Hz on the condition of no load and 23.4Hz on the condition of load  thus the method is feasible. 2010 IEEE.  rapidity and miniaturization of the micro-electromechanical actuator power system based on the ball screw. First  according to specific technical indexes  the power  electromechanical time constant and the size of the motors are screened originally through theoretical analysis. Finally  based on the characteristics of ball screw transmission  load locus of the micro-electromechanical actuator dynamic system is theoretically analyzed and the optimum speed ratio is determined through parameter optimization. The results of the double closed loop controlled test on the principle prototype show: the system can operate normally with 2.5N.m hinge moment