Quantitative Analysis of Pb, Cd, Cr and Cu in Soil Using Standard Addition Method Combined with Laser-Induced Breakdown Spectroscopy 期刊论文  OAI收割
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 卷号: 37, 期号: 10, 页码: 3274-3280
作者:  
Fang Li;  Zhao Nan-jing;  Ma Ming-jun;  Meng De-shuo;  Gu Yan-hong
  |  收藏  |  浏览/下载:22/0  |  提交时间:2019/06/17
Thickness Measurement of Ultrathin SiO2 Layer on Si by Using XPS Standard Curve 期刊论文  OAI收割
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 卷号: 30, 期号: 6, 页码: 1670-1673
作者:  
Zhao Zhi-juan;  Liu Fen;  Wang Hai;  Zhao Liang-zhong;  Yan Shou-ke
  |  收藏  |  浏览/下载:19/0  |  提交时间:2019/04/09
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wang J.;  Liu Y.;  Liu Y.;  Liu Y.;  Sun Q.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation  the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results  the reference gains and the dynamic range of temperature measurement were obtained. Finally  the uncertainty influencing the calibration results was analyzed  the analysis shows the maximal uncertainty is 5.2%  which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
图像特征检测与匹配研究 学位论文  OAI收割
工学博士, 中国科学院自动化研究所: 中国科学院研究生院, 2008
作者:  
王志衡
收藏  |  浏览/下载:84/0  |  提交时间:2015/09/02
Study and calibration of azimuth effect in multi-position strap-down north seeking system (EI CONFERENCE) 会议论文  OAI收割
7th World Congress on Intelligent Control and Automation, WCICA'08, June 25, 2008 - June 27, 2008, Chongqing, China
作者:  
Wang Z.;  Zhao J.;  Wang Z.
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
In order to reduce the influence of azimuth effect in multi-position strap-down north seeking system  its cause of formation is studied based on the precession principle of the dynamically tuned gyro. A detecting system  composed by true north prism  two Leica theodolites and benchmark prism fixed in the strap-down north seeking system  was designed to calibrate the azimuth effect. By two steps  many measurements are gone on in every position to eliminate the random error. According to the homologous between the error and the position  a sinusoid is made a fit as compensate curve after the error of twelve positions is measured. Then the azimuth effect of the arbitrary position can be corrected by the curve. The experiment result shows that the seeking north standard deviation is only 11.77 after compensation  which is considerably less than the 87.75 without correction. 2008 IEEE.  
Research on the nonuniformity correction of linear TDI CCD remote camera (EI CONFERENCE) 会议论文  OAI收割
Advanced Materials and Devices for Sensing and Imaging II, November 8, 2004 - November 10, 2004, Beijing, China
Ya-xia L.; Zhi-hang H.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
Many applications  such as industrial inspection and overhead reconnaissance benefit from line scanning architectures where time delay integration (TDI) significantly improves sensitivity[5]. Images with linear response have become the backbone of the imaging industry. But each pixel of the TDI CCD has unique light sensitivity characteristics. Because these characteristics and the lens of the optical system affect camera's linearization and its performance  they must be removed through calibration. The process by which a CCD image is calibrated is known as nonuniformity correction. This paper discusses several methods of nonuniformity correction[2]. The first is one-point correction technique  which requires only one calibration point. This approach is to shift each curve toward the nominal curve by subtracting the offset from or adding the offset to the average. The second is two-point correction technique  which requires two calibration points. Each point is rotated and aligned so that all the detectors have the same response under the same radiance. The third is multipoint correction. It is recommended that more calibration points be implemented at appropriate regions of the response curve. Depend on the linear photoelectric response of the TDI CCD  we use two-point calibration and the standard deviations for the images are given before and after the correction.  
Anodic Stripping Voltammetry at Bismuth-Coated and Uncoated Carbon Microdisk Electrodes:Application to Trace Metals Analysis in Flood Samples 期刊论文  OAI收割
Analytical letters, 2004, 卷号: 37, 期号: 5, 页码: 995-1011
BALDO Maria Antonietta; DANIELE Salvatore
  |  收藏  |  浏览/下载:19/0  |  提交时间:2010/12/28