中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [5]
西安光学精密机械研究... [2]
采集方式
OAI收割 [7]
内容类型
会议论文 [7]
发表日期
2019 [1]
2013 [1]
2011 [2]
2007 [1]
2005 [2]
学科主题
航空、航天 [1]
筛选
浏览/检索结果:
共7条,第1-7条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Micro-vibration test and imaging analysis during space camera thermal-optical test
会议论文
OAI收割
Beijing, China, 2019-07-07
作者:
She, Wenji
;
Cui, Kai
;
Gao, Xiong
;
Li, Shuxiu
;
Wang, Huan
  |  
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2020/03/04
Space Camera
Micro-vibration
MTF
Accelerometer
Thermal-optical Test
Structural design of large aperture rectangular mirror for space telescope (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Civil Engineering and Transportation, ICCET 2012, October 27, 2012 - October 28, 2012, Guilin, China
作者:
Li Z.
;
Li Z.
收藏
  |  
浏览/下载:43/0
  |  
提交时间:2013/03/25
Structural design of large aperture mirror is one of the key technologies for space telescope development. To meet the requirements of high stiffness
strength and thermal dimensional stability
some factors such as support scheme
materials selection
lightweight design and flexible support design were taken into account. The three supports location of the mirror was determined according to the modal analytical solution. By adjusting the parameters of flexure hinge
influences of gravity
assembly stress and thermal stress on the mirror were reduced obviously. Finite element analysis (FEA) results indicate that the surface accuracy reach to rms10.2nm and 10.8nm under the gravity along optical axis direction and 5C uniform temperature rise respectively
the fundamental frequency of the mirror component is 268Hz. Dynamics test shows that the first order natural frequency is 256Hz
which shows an error less than 5% compared to FEA results. (2013) Trans Tech Publications
Switzerland.
Precise Thermal Control of CCD Assembly of Space Optical Remote Sensor
会议论文
OAI收割
第七届国际精密工程测量与仪器学术研讨会, 云南丽江, 2011-08-07
Yang WG(杨文刚)
;
Li YF(李一凡)
;
He TB(贺天兵)
;
Bai Z(白喆)
;
Zhang XH(张向辉)
;
Wang YH(王英豪)
;
Yu L(余雷)
;
Fu WC(傅伟纯)
;
Li YC(李英才)
收藏
  |  
浏览/下载:41/0
  |  
提交时间:2011/12/29
CCD
precise thermal control
thermal analysis
thermal balance test
space optical remote sensor
Application of particulate reinforced aluminum matrix composite in airborne photoelectric turret (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electric Information and Control Engineering, ICEICE 2011, April 15, 2011 - April 17, 2011, Wuhan, China
作者:
Wang P.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
In order to design and manufacture more excellent airborne photoelectric stable turret
modulus of elasticity of 213 GPa and thermal expansion coefficient of 7.9106/K. The frame has decreased the maximum deformation by by 60% and increased the fundamental frequency by 65% as compared with those of aluminum alloy materials
a new type of aeronautical material-particulate reinforced aluminum matrix composite (SiC/Al composite) is investigated. Several crucial technologies
respectively as shown by finite element analysis results. Those are confirmed by vibration test furthermore. Therefore
such as pressureless infiltration technology
a significant lightening effect is achieved and the thermal control load is also reduced. The test result indicates that the stable accuracy of the system achieves 19.8rad and the optical-axis parallelism of pay load is 0.1mrad. The research applies the SiC/Al composites to airborne photoelectric platforms
interface reaction controls and plate's welding are systematically studied. Then
which makes a effective exploration for the new aeronautical material's application. 2011 IEEE.
using SiC/Al composites
the airborne photoelectric stable turret frame is successfully prepared in density of 2.94 g/ cm3
Fabrication technique of large-scale lightweight SiC space mirror (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Large Mirrors and Telescopes, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Zhang G.
;
Zhang G.
;
Zhang G.
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2013/03/25
Silicon carbide (SiC) is a new type candidate material for large-scale lightweight space mirror. Its low thermal distortion
high stiffness
high optical quality
and its dimensional stability are better than other traditional optical substrate materials such as ULE
Zerodure
Beryllium (Be) and so on. In this paper
the lightweight silicon carbide space mirror blank was fabricated by reaction sintering. As a space born mirror material
silicon carbide must be an optical grade ceramic. So we prepared the silicon carbide green body with gel-casting method. Then some carbon materials were supplemented into the green body which will bring reaction-sintering with silicon in a vacuum furnace during 1500-1600C
ultimately the reaction bonded silicon carbide was made. The diameter of SiC space mirror blank we have made is 680mm. If expanding the size of the vacuum furnace
bigger mirror blank can be obtained. The test results show that the mechanical and thermal properties of RB-SiC are excellent with bending strength of 350MPa
fracture toughness of 4.1 MPa·m1/2 and coefficient of thermal expansion(CET) of 2.6710-6/K. The surface roughness(RMS) could be better than 3nm.
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.
;
Li H.
;
Chen C.
;
Zhou C.
;
Qian S.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal
spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle
optical system
mechanical constructions
DC serve motor control system
array detector
data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy
low cost
multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.
Manufacturing and Testing SiC Aspherical mirrors in Space telescopes (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
作者:
Fan D.
;
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2013/03/25
Reaction Bonded (RB) SiC mirrors due to their excellent specific stiffness and thermal properties have been widely used in space telescopes. However
polishing large SiC aspherical mirrors is difficult compared to other materials such as fused silica or Zerodu. In addition
surface roughness of the polished SiC mirrors is limited by the defects of the materials and needs to be improved by means of surface coating technique. This paper introduces the current progress of large SiC aspherical mirrors manufacturing and testing in CIOMP. In particular
the procedures of making large off-axis aspherical mirrors were discussed in detail. A proprietary computer controlled optical surfacing (CCOS) technique was utilized to grind and polish the mirrors and the computer aided null test was used to measure the surface figure. As results
a 600mm class off-axis SiC aspherical mirrors was demonstrated with figure error less than 13nm rms.