The research of round raster readheads scheme (EI CONFERENCE)
会议论文
OAI收割
3rd international Conference on Manufacturing Science and Engineering, ICMSE 2012, March 27, 2012 - March 29, 2012, Xiamen, China
Cong J.-F.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
The round raster is extensively applied in all kinds of high accuracy angular displacement measurement and control system. With the development of precise mechanotronics measuring instrument
machining center
CNC machine and various precise location testing technology
a higher request is put forward to the accuracy and the function of raster measurement system. In this article it is concluded that double readheads is the most reasonable configuration scheme through tests of single readhead scheme
two readheads and four readheads. (2012) Trans Tech Publications.
Study of horizontal shafting with spherical four-way structure (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
作者:
Yang L.
;
Yang L.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
Altazimuth photoelectric theodolite level shaft U-type and T-type structure
but with the expanding field of applications of photoelectric theodolite
the horizontal shaft structure occur great changes. For example
in the marine environment
shipboard conditions
the instrument has a waterproof
corrosion-resistant
easy maintenance and other functions
while carrier-based optoelectronic devices from a single visible television configure the development of integrated infrared system and ranging system as one of the single-station measurement system
due to the spherical structure has sufficient internal space exactly adapted to this need. In this paper
the horizontal axis of a spherical four-way structure. From aspects of the spherical four-way split in the form and shafting design and finite element analysis of the detailed design. A spherical four-way horizontal axis system
diameter 550mm
weight 19kg sphere
in the 40kg load
the maximum deformation of 3.3m
fully meet the requirements. The shaft of the structure of the shaking is less than 2 arc seconds
the vibration test
the re-examination instrument accuracy change is less than 1 arc seconds. Verify that the structure is stable and reliable. 2012 IEEE.
Imaging system effects on the measuring accuracy of the optical surface in interferometer (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
Yang W.
;
Liu M.
;
Xu W.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
In order to measure high accuracy or mid spatial frequency optical surfaces
this study investigated imaging system in Fizeau interferometer. Interferometer is a transferring phase information system. General transfer function can't evaluate the ability of imaging system in interferometer that transfers the phase information of the optical surface. So this paper deduced instrument transfer function (ITF) and used ITF to evaluate the phase information transfer ability of interferometer. We obtained some results about ITF of imaging system by numerical simulation when there are different aberrations in imaging system or measuring optical surfaces were different. Our results indicate that ITF can evaluate the ability of transferring phase information in interferometer and the distortion of imaging system evidently affects the accuracy of interferometric measurements. 2010 IEEE.
The error analysis of automated biochemical analyzer (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Computing, Information and Control, ICCIC 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Qinghai C.
;
Yihui W.
;
Haiwen L.
;
Peng H.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
In order to find out the relationships between the four error sources
namely
locating error
optics system fluctuations
sampling error and temperature fluctuations
and the accuracy of the instrument
we analyzed each relationship of them
and found that the effect of locating error is so tiny that it can be ignored
finally established the total error model and the model of the allowed noise of the optics system of the instrument. Analysis and the models may supply a reliable theory evidence for the improvement of the instrument and the designing of similar instruments. 2011 Springer-Verlag.
Design of VxWorks-based software architecture for space optical remote sensor (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Tao Y.
;
Song K.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
In order to satisfy requirements of real time and parallel control for the space optical remote sensor and implement the high integration of software
a kind of VxWorks-based multitask software architecture was put forward. Firstly
the technological requirements of optical remote sensor were analyzed in detail and functions and performances of the optical remote sensor were fixed. Task that was based on each function of optical remote sensor was compartmentalized. Then
software architecture of optical remote sensor was designed. Finally
experiments were carried out and results verified the accuracy and feasibility of the software architecture. Test results showed that the software architecture satisfied the requirements of real time and parallel control for the space optical remote sensor
its functions and performances met the system design target perfectly
and the software architecture was applicable to the engineering application of space instrument. 2011 IEEE.
Measuring instrument for radial composite deviations of high-precision master gear (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
作者:
Zhang Y.
;
Wang L.
;
Wang L.
;
Wang L.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
During double flank rolling composite detection
the radial composite deviations of master gears has been existed and transferred to the measured gear by the primary harmonic curve. In order to improve measurement accuracy
a measuring instrument is developed for radial composite deviations of high-precision master gear in the paper. This instrument uses the structure of spring-suspend swing span to overcome the shortcomings of large rotation errors
low sensitivity
low resolution and large measuring force appearing in the traditional combination-type gear inspection instrument. Artificial intelligence technology is used to improve the efficiency and accuracy of this instrument. The result is that the measuring apparatus is able to meet the requirement and improve efficiency through the measuring experiments on master gears of precision grade 2 with modulus 2 mm and 3 mm
respectively. 2010 SPIE.
Application of precision harmonic gear drive in focusing mechanism of space camera (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Smart Structures and Materials in Manufacturing and Testing, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
A kind of precision harmonic gear drive in the focusing mechanism of space camera is studied
which adopt external meshing complex wave transmission mode. Wave generator is combined with an elliptic cam and a flexible bearing around it. Flexspline is a structure of single wave with the same teeth. The output shaft is supported by a single cross-roller bearing. Ball screws connected the output shaft translate the rotational motion to the linear motion
and drive the focusing mirror repeated moving along the linear guide. The output rigid wheel is connected with absolute encoder to detect displacement of focusing movement. It has the characteristics of big transmission ratio
high precision
compact structure
high efficiency and smooth running etc. According to the practical application of this harmonic gear drive in the space camera
the location relationship between the displacement of focusing structure and the focal plane movement is derived
and the system error is analyzed
its accuracy is tested with the open-loop control method. Experimental results show that transmission ratio of the instrument is 1:70
repeated positional accuracy is 2m
which meet the requirements for use. 2010 SPIE.
In situ long trace profiler for measurement of Wolter type-I mirror (EI CONFERENCE)
会议论文
OAI收割
Advances in Metrology for X-Ray and EUV Optics III, August 1, 2010 - August 2, 2010, San Diego, CA, United states
作者:
Chen B.
;
Chen B.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
The surface profile of Wolter type-I mirror has a great impact on the performance of Solar X-ray Telescope. According to the existing fabrication instrument and experimental conditions in our lab
an in situ Long Trace Profiler is developed and set up on the fabrication instrument in order to measure the surface profile of Wolter mirror in real time during fabrication process. Its working mechanism
structural parameters and data processing algorithm are investigated. The prototype calibrated by a standard plane mirror is used to measure a sample of Wolter type-I mirror. The results show that our prototype can achieve an accuracy of 2.6rad rms for slope error with a stability of 1.33rad during the whole measurement period. This can meet further fabrication requirements. 2010 Copyright SPIE - The International Society for Optical Engineering.
Development of a new diffuse near infrared food measuring (EI CONFERENCE)
会议论文
OAI收割
Sitxh International Symposium on Instrumentation and Control Technology: Signal Analysis, Measurement Theory, Photo-Electronic Technology, and Artificial Intelligence, October 13, 2006 - October 15, 2006, Beijing, China
作者:
Zhang J.
;
Zhang J.
;
Zhang J.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
Industries from agriculture to petrochemistry have found near infrared (NIR) spectroscopic analysis useful for quality control and quantitative analysis of materials and products. The general chemical
polymer chemistry
petrochemistry
agriculture
food and textile industries are currently using NIR spectroscopic methods for analysis. In this study
we developed a new sort NIR instrument for food measuring. The instrument consists of a light source
12 filters to the prismatic part. The special part is that we use a mirror to get two beams of light. And two PbS detectors were used. One detector collected the radiation of one light beam directly and the value was set as the standard instead the standard white surface. Another light beam irradiate the sample surface
and the diffuse light was collected by another detector. The value of the two detectors was compared and the absorbency was computed. We tested the performance of the NIR instrument in determining the protein and fat content of milk powder. The calibration showed the accuracy of the instrument in practice.
Analysis of a precise instrument for measuring reference level involute (EI CONFERENCE)
会议论文
OAI收割
Third International Symposium on Precision Mechanical Measurements, August 2, 2006 - August 6, 2006, Xinjiang, China
作者:
Zhang Y.
;
Wang X.
;
Wang X.
;
Wang X.
;
Wang L.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
Reference level involute is used for evaluating other involutes
but it is very difficult to measure reference level involute exactly. Nowadays the available methods for measuring precise involute include single base disc mode
electronic generation mode
and CNC three-coordinate mode. But measurement accuracy of the modes above is not suitable for reference level involute. A precise instrument for measuring reference level involute
double base discs instrument
is introduced. It is consistent with generation principle of the involute entirely. Besides having the advantages of single basic disc instrument
the instrument can remove Abbe error caused by the stylus
and has no pressure deforming. The instrument's structure is described. The main sources of measurement errors are analyzed and methods for compensation are presented. Finally
uncertainty of the instrument is given
which meets reference level involute test specification.