Focused ion beam preparation of microbeams forin situmechanical analysis of electroplated nanotwinned copper with probe type indenters
期刊论文
OAI收割
JOURNAL OF MICROSCOPY, 2020, 卷号: 279, 期号: 3, 页码: 212-216
作者:
Robertson, Stuart
;
Doak, Scott
;
Sun, Fu-Long
;
Liu, Zhi-Quan
;
Liu, Changqing
  |  
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2021/02/02
Chunk lift-out
focused ion beam
in situ
micromechanical testing
nanotwinned copper
P-FIB
Phased Array Detection Parameters for Electron Beam Welds in CFETR Vacuum Vessel Port Stubs
期刊论文
OAI收割
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 卷号: 48
作者:
Fu, Yunpeng
;
Wu, Jiefeng
;
Liu, Zhihong
;
Wang, Rui
;
Jiang, Beiyan
  |  
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2020/11/26
Acoustic field simulation
China Fusion Engineering Testing Reactor (CFETR)
electron beam welding (EBW)
phased array ultrasonic testing (PAUT)
Influences of the three-phase boundary on the electrochemical corrosion characteristics of carbon steel under droplets
期刊论文
OAI收割
Materials and Corrosion-Werkstoffe Und Korrosion, 2013, 卷号: 64, 期号: 4, 页码: 309-313
Y. H. Wang
;
Y. Y. Liu
;
W. Wang
;
L. Zhong
;
J. Wang
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/12/24
atmospheric corrosion
carbon steel
droplet
three-phase boundary
wire
beam electrode
wire-beam electrode
chloride solution droplets
localized corrosion
stainless-steel
testing method
oil coatings
zone
tool
Dielectric properties and resistance to fatigue failure of different barrier layers prepared on flexible stainless-steel foils by ion-beam assisted deposition
期刊论文
OAI收割
THIN SOLID FILMS, 2012, 卷号: 520, 期号: 21, 页码: 6556-6560
作者:
Li YQ(李玉琼)
;
Yu ZN
;
Leng J
;
Wang HQ
;
Chen S(陈涉)
收藏
  |  
浏览/下载:19/0
  |  
提交时间:2013/01/18
Barrier layer
Composite barrier
Dielectric properties
Fatigue testing
Stainless-steel foil
Ion beam assisted deposition
Metal oxides
Film Solar-Cells
Thin-Films
Efficiency
TiO2
Optimum design of laser encoding and decoding on laser beam-riding guidance (EI CONFERENCE)
会议论文
OAI收割
2nd International Conference on Frontiers of Manufacturing and Design Science, ICFMD 2011, December 11, 2011 - December 13, 2011, Taichung, Taiwan
作者:
Yang L.
;
Yang L.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
Operating principle of laser beam-riding guidance was set forth. Based on the principle of spatial frequency-encoding
experimental results demonstrated that the receiver can receive correctly the encoded signal and can decode the signal
an optimum laser encoding mode was designed
measurement for the missdistance is feasible and all the performance parameters satisfy the demand. (2012) Trans Tech Publications
which can transfer continuous laser into pulse laser that represents different position information. Then the mathematic model of deviation from target is built
Switzerland.
a modified encoding pattern was presented
which is composed of two light paths crossed 90. Azimuth information of target is given in orthogonal coordinate system and deviation from target is linearity. As well as
characteristic distribution of spatial laser field is analyzed. Corresponding decoding mode was presented
by testing in 2 kilometers outdoor
The design of computer-generated holograms for testing unsymmetrical optical surfaces (EI CONFERENCE)
会议论文
OAI收割
2012 International Symposium on Photonics and Optoelectronics, SOPO 2012, May 21, 2012 - May 23, 2012, Shanghai, China
作者:
Zhang X.
;
Zhang Y.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
It is a technical difficulty to test the unsymmtrical optical surfaces in non-contact methods. But we can do it using computer-generated holograms (CGH). The principle and design of the CGH have been discussed in the paper. Take the cubic suface as an example
The order separation of the CGH is analyzed theoretically and the simulation result of the order separation is given in the paper. We develop the binary process of the continuous CGH phase function and get the sample of the amplitude CGH. A CGH for testing a cubic phase plate with duty cycle 0.5 is fabricated by using e-beam lithographic techniques. In this situation
the contrast of the interference fringe pattern can achieve a level of 99.4% by calculation. 2012 IEEE.
Novel correction method for X-ray beam energy fluctuation of high energy DR system with a linear detector
期刊论文
OAI收割
CHINESE PHYSICS C, 2011, 卷号: 35, 期号: 11, 页码: 1074-1078
作者:
Yang Min
;
Chen Hao
;
Meng Fan-Yong
;
Wei Dong-Bo
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/10/29
X-ray testing
accelerator
X-ray beam energy fluctuation
high pass filter
artifacts
Design of co-path scanning long trace profiler for measurement of X-ray space optical elements (EI CONFERENCE)
会议论文
OAI收割
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Shun L.
;
Yan G.
;
Wei Z.
;
Yang Z.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
The Long Trace Profiler (LTP) is a precision surface slope error measurement instrument used in synchrotron radiation optics for many years. By making some modifications to the LTP system
we developed a co-path scanning LTP (CSLTP) system to test the cylindrical aspherical surface which used in X-ray space optics. To reduce the mistake caused by air turbulence and manufacture faults of optical elements used
the CSLTP is designed with the least difference between the testing beam path and the reference beam path. Also
it uses multiple-beam interference but double beam interference to reduce the width of beam fringe. This improves the position precision of the beam fringe on the image plane. 2010 SPIE.
Accurate determination of subnanoscale deformation with combined laser calorimetry and surface thermal lens technique
期刊论文
OAI收割
APPLIED PHYSICS LETTERS, 2009, 卷号: 94, 期号: 13
作者:
Liu, Mingqiang
;
Li, Bincheng
;
Wang, Yanru
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2015/09/21
calorimetry
deformation
measurement by laser beam
nanomechanics
optical elements
optical films
optical testing
silicon compounds
thermal lensing
wavefront sensors
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:
Song K.-F.
;
Li J.-L.
;
Zhang W.-L.
;
Wang Y.-L.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
In the device
a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source
and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system
so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least
the sample fluorescence through the integrating sphere and come to the grating monochromator
The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device
SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process
signal-to-noise ratio(SNR) will be improved
also adjust delay time
ampling frequency and sampling number arbitrarily. By testing
the sensitivity is 10-12mol/L(substance marked by Eu3+)
examination repeat is &le2.5%
examination linearity is from 10 -8mol/L to 10-12mol/L
correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody
and solve the tumor
genetic variation
the virus protein detection. 2009 SPIE.