中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [2]
沈阳自动化研究所 [2]
数学与系统科学研究院 [1]
国家天文台 [1]
高能物理研究所 [1]
采集方式
OAI收割 [7]
内容类型
期刊论文 [4]
会议论文 [3]
发表日期
2022 [1]
2017 [1]
2016 [1]
2014 [1]
2013 [1]
2012 [1]
更多
学科主题
Physics [1]
筛选
浏览/检索结果:
共7条,第1-7条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Global and Asymptotically Efficient Localization From Range Measurements
期刊论文
OAI收割
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2022, 卷号: 70, 页码: 5041-5057
作者:
Zeng, Guangyang
;
Mu, Biqiang
;
Chen, Jiming
;
Shi, Zhiguo
;
Wu, Junfeng
  |  
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2023/02/07
Range measurements
TOA localization
two-step localization
large-sample analysis
A model of the time-variable gravity field inverted from combined GRACE on-board GPS and KBR range rate data
期刊论文
OAI收割
CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2017, 卷号: 60, 期号: 7, 页码: 2568
作者:
  |  
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2021/12/06
GRACE
Time-variable gravity field
K-band range-rate measurements
On-board GPS observations
Combined solution
Deep sea AUV navigation using multiple acoustic beacons
期刊论文
OAI收割
China Ocean Engineering, 2016, 卷号: 30, 期号: 2, 页码: 309-318
作者:
Ji DX(冀大雄)
;
Song W(宋伟)
;
Zhao HY(赵宏宇)
;
Liu J(刘健)
收藏
  |  
浏览/下载:38/0
  |  
提交时间:2016/04/30
deep sea AUV
acoustic navigation
range measurements
multiple beacons
outlier recognition
An Elasticity Inspired method for multi-AUVs formation control using range-only measurements
会议论文
OAI收割
OCEANS 2014 MTS/IEEE Taipe, Taipei, Taiwan, April 7-10, 2014
作者:
Xu HL(徐红丽)
;
Li GN(李冠男)
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2014/12/29
formation control
multi-AUVs system
range-only measurements
elasticity inspired method
The approximate calculation of atmospheric path radiance in close range and horizontal direction (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Sensors, Measurement and Intelligent Materials, ICSMIM 2012, December 26, 2012 - December 27, 2012, Guilin, China
作者:
Sun Z.
;
Chen Y.
;
Zhang Y.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
Atmospheric path radiance is the key factor in the accuracy of objective radiation measurement. In the traditional radiation character measurements
it is compared with the results of MODTRAN and measurement in experiment. It is revealed that the accuracy of software is 7.8%
under the help of the atmospheric observation equipment
and the formula is 4.9%
MODTRAN and other software likewise
which could demonstrate the validity of the pproximate calculation formula in close range and horizontal direction. In this article
the indeterminacy rate could be around 10~20%
in the process of deducing and experiment
it is highly restricts the measurement accuracy of objective radiation. For this reason
the validity of the approximate calculation formula in close range and horizontal direction is fully proved
it is quite significant to develop the study of measure and calculation in path radiance. The approximate calculation formula for path radiance in close range and horizontal direction is expressed in this article
which supply a new method in approximate calculation of path radiance for objective radiation measurement. (2013) Trans Tech Publications
Switzerland.
Comparison of radiation temperature measurement precision between middlewave and longwave thermal-imaging systems (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
作者:
Sun Z.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
A comparison study on temperature measurement precision between middlewave 3-5m and longwave 8-12m measuring thermal imaging systems has been conducted. The study was limited to systems working in indoor conditions and the target's temperature is in the range of 270K900K. First
the Disturb Resisting Function (DRF) of infrared systems is deduced. On the base of DRF curve
we find that the middlewave infrared system get the smaller influences under the same size disturb compared with the longwave system. A theory of the influence of target's physical characteristic and measurement conditions on the accuracy of temperature measurements has been developed. On the basis of the developed formulas an analysis of the influence of signal disturbances (because of incorrectly assumed emissivity
limited transmittance of the atmosphere
radiation reflected by the object and shift of optics radiation) on the accuracy of temperature measurement has been made. It has been found that the middlewave systems in typical temperature range offer generally better accuracy in temperature measurement than the longwave ones do. 2012 IEEE.
The Alpha Magnetic Spectrometer (AMS) on the International Space Station: Part I - results from the test flight on the space shuttle
期刊论文
OAI收割
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 2002, 卷号: 366, 期号: 6, 页码: 331-405
作者:
AMS Collaboration
收藏
  |  
浏览/下载:18/0
  |  
提交时间:2015/12/02
NEAR-EARTH ORBIT
COSMIC-RAY POSITRON
TOTAL CROSS-SECTIONS
ENERGY-RANGE
GEOMAGNETIC-FIELD
HELIUM SPECTRA
LIGHT-NUCLEI
DARK-MATTER
NEUTRALINO ANNIHILATION
BALLOON MEASUREMENTS