中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [4]
深海科学与工程研究所 [1]
采集方式
OAI收割 [5]
内容类型
会议论文 [4]
期刊论文 [1]
发表日期
2023 [1]
2012 [1]
2011 [1]
2007 [1]
2005 [1]
学科主题
筛选
浏览/检索结果:
共5条,第1-5条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Translational and Rotational Motion Measurement of a Spherical Particle in Hydraulic Collecting
期刊论文
OAI收割
INTERNATIONAL JOURNAL OF OFFSHORE AND POLAR ENGINEERING, 2023, 卷号: 33, 期号: 3, 页码: 307-315
作者:
Xiong, Hong
;
Chen, Yuxiang
;
Cheng, Hui
;
Zhu, Hong
;
Yu, Chunliang
  |  
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2024/02/06
Solid-liquid two-phase flow
spherical detector
hydraulically collecting
translational and rotational motion
Nanoscale patterns made by using a 13.5-nm Schwarzschild objective and a laser produced plasma source (EI CONFERENCE)
会议论文
OAI收割
Optical Micro- and Nanometrology IV, April 16, 2012 - April 18, 2012, Brussels, Belgium
作者:
Wang X.
;
Wang X.
;
Wang X.
;
Wang Z.
;
Wang Z.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
Lithium fluoride (LiF) crystal is a very promising candidate as nanometer resolution EUV and soft X-ray detector. Compared with other EUV and soft X-ray detectors
charge coupled device and photographic films
LiF crystal has high resolution
large field of view and wide dynamic range. In this paper
using LiF crystal as EUV detector and a Schwarzschild objective (SO) working at 13.5nm as projection optics
mesh images with 4.2 m
1.2 m and 800 nm line width and pinhole patterns with 1.5m diameter are acquired in projection imaging mode and direct writing mode
respectively. Fluorescence intensity profiles of images show that the resolution of mesh image is 900 nm
and the one of pinhole image is 800 nm. In the experiments
a spherical condense mirror based on normal incidence type is used to eliminate the damage and contamination on the masks (mesh and pinhole) caused by the laser plasma
and the energy density is not decreased compared with that the masks are close to the plasma. The development of the SO
the alignment of the objective and the imaging experiments are also reported. 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
Design of dual-FOV refractive/diffractive LWIR optical system (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Wang L.-J.
;
Zhang J.-P.
;
Wang L.-J.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
An infrared-optical zoom system using binary element is proposed in this paper. The two main advantages of the zoom system introducing here are: bigger F-number and lower cost. The primary optical properties are: F/#=1
Second
Others
zoom ratio =1:4
binary element is used to correct the chromatical aberration by taking the advantage of negative dispersion characteristics and the cost of the system is lower than that of conventional ones with Zinc Selenide (Znse) material at the same level. In the binary element is rotational symmetric with one step which is easy to fabricate
in order to balance 5th spherical aberration
and dual field are 26.6 and 5.6respectively. Wider field of view is used for search and the smaller one is used for imaging details. This system uses un-cooled infrared detector with 320240 pixels and 45m pixel size. The F-number matches the sensitivity range of the detector array. Three aspects are considered during design process to make the system more satisfactory and more achievable. First
5th coma aberration and 5th astigmatic aberration
the manner of zoom is accomplished by exchanging tow lenses into the smaller field of view system layout. The lens exchange manner faces the requirement of simple system structure and good image quality in both focal points. It can also make the system more feasible in the alignment process than mechanical-zooming manner and optical-zooming manner
high-order asphere surfaces with 2th order to 10 th order are also hired in the system. Asphere surface is useful in compressing the system and improving optical system transmittance. This kind asphere surface is on industrial level featuring low cost and easy to fabricate. It is shown that good image quality can achieved by implementing five Germanium lenses and the transmittance of system is 72%. All aberrations are diffraction-limited
both spherical aberration and astigmatic aberration are corrected. When the field of view(FOV) is 26.6 and the focal length is 152mm
MTF at Nyquist frequency(11lp/mm) is great than 0.7. The spherical aberration is -0.0073. The coma aberration is 0.0978 and the astigmatic aberration is -0.013. When the field of view(FOV) is 5.6 and the focal length is 38mm
MTF at Nyquist frequency is great than 0.8 with spherical aberration -0.0046
the coma aberration 0.055 and astigmatic aberration 0.034.
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.
;
Li H.
;
Chen C.
;
Zhou C.
;
Qian S.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal
spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle
optical system
mechanical constructions
DC serve motor control system
array detector
data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy
low cost
multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.