Automatic Defect Detection Instrument for Spherical Surfaces of Optical Elements
期刊论文
OAI收割
PHOTONICS, 2024, 卷号: 11, 期号: 7, 页码: 13
作者:
Shi, Yali
;
Zhang, Mei
;
Li, Mingwei
  |  
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2024/09/09
computer vision
defect detection
spherical optical element
Design of dual-FOV refractive/diffractive LWIR optical system (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Wang L.-J.
;
Zhang J.-P.
;
Wang L.-J.
;
Zhang X.
;
Zhang X.
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2013/03/25
An infrared-optical zoom system using binary element is proposed in this paper. The two main advantages of the zoom system introducing here are: bigger F-number and lower cost. The primary optical properties are: F/#=1
Second
Others
zoom ratio =1:4
binary element is used to correct the chromatical aberration by taking the advantage of negative dispersion characteristics and the cost of the system is lower than that of conventional ones with Zinc Selenide (Znse) material at the same level. In the binary element is rotational symmetric with one step which is easy to fabricate
in order to balance 5th spherical aberration
and dual field are 26.6 and 5.6respectively. Wider field of view is used for search and the smaller one is used for imaging details. This system uses un-cooled infrared detector with 320240 pixels and 45m pixel size. The F-number matches the sensitivity range of the detector array. Three aspects are considered during design process to make the system more satisfactory and more achievable. First
5th coma aberration and 5th astigmatic aberration
the manner of zoom is accomplished by exchanging tow lenses into the smaller field of view system layout. The lens exchange manner faces the requirement of simple system structure and good image quality in both focal points. It can also make the system more feasible in the alignment process than mechanical-zooming manner and optical-zooming manner
high-order asphere surfaces with 2th order to 10 th order are also hired in the system. Asphere surface is useful in compressing the system and improving optical system transmittance. This kind asphere surface is on industrial level featuring low cost and easy to fabricate. It is shown that good image quality can achieved by implementing five Germanium lenses and the transmittance of system is 72%. All aberrations are diffraction-limited
both spherical aberration and astigmatic aberration are corrected. When the field of view(FOV) is 26.6 and the focal length is 152mm
MTF at Nyquist frequency(11lp/mm) is great than 0.7. The spherical aberration is -0.0073. The coma aberration is 0.0978 and the astigmatic aberration is -0.013. When the field of view(FOV) is 5.6 and the focal length is 38mm
MTF at Nyquist frequency is great than 0.8 with spherical aberration -0.0046
the coma aberration 0.055 and astigmatic aberration 0.034.
Developing of in-suit long trance profiler for testing slope error of aspherical optical Elements (EI CONFERENCE)
会议论文
OAI收割
ICO20: Optical Devices and Instruments, August 21, 2005 - August 26, 2005, Changchun, China
Zhou C.
;
Li H.
;
Chen C.
;
Zhou C.
;
Qian S.
收藏
  |  
浏览/下载:36/0
  |  
提交时间:2013/03/25
Profile error of super smooth surface of optical elements at X-ray/EUV in synchrotron radiation (SR) light beam line is described as slope error of them generally. The Long Trace Profiler (LPT) is used for testing surface slope error of SR optical elements in world generally. It is requisite to use In-suit LTP measuring surface thermal distortion of SR optical elements with high heat under high bright SR source. Authors design an In-suit LTP by means of co-path interferometer with pencil light beam. The instrument not only can be used for testing slope error of mirrors in Lab. also in situation test the distortion of mirror with high heat load at synchrotron light beam line. The device can be used to test various absolute surface figures of optical elements such as aspherieal
spherical and plane. It is needless standard reference surface. It is named by LTP-III. This paper describes its basic operating principle
optical system
mechanical constructions
DC serve motor control system
array detector
data acquisition system and computer system for controlling and data analysis of LTP-III. The Instrument has advantages of high accuracy
low cost
multifunction and wide application. Length of surface measured of optical element accuracy is 0.04 arcsec.