中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
半导体研究所 [3]
长春光学精密机械与物... [1]
高能物理研究所 [1]
近代物理研究所 [1]
紫金山天文台 [1]
采集方式
OAI收割 [6]
iSwitch采集 [1]
内容类型
期刊论文 [5]
会议论文 [2]
发表日期
2018 [3]
2011 [1]
1999 [3]
学科主题
半导体物理 [2]
筛选
浏览/检索结果:
共7条,第1-7条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
COMPASS-A COMPAct decay spectroscopy set-up
期刊论文
OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 卷号: 907, 页码: 81-89
作者:
Ackermann, D.
;
Mistry, A. K.
;
Hessberger, F. P.
;
Andel, B.
;
Antalic, S.
  |  
收藏
  |  
浏览/下载:70/0
  |  
提交时间:2018/10/08
alpha
gamma
CE and X-ray spectroscopy
Si strip detector
Digital electronics
Large volume Ge detectors
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
期刊论文
OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 卷号: 893, 页码: 43-56
作者:
Tykhonov, A.
;
Ambrosi, G.
;
Asfandiyarov, R.
;
Azzarello, P.
;
Bernardini, P.
  |  
收藏
  |  
浏览/下载:55/0
  |  
提交时间:2019/04/08
Cosmic-ray detectors
Gamma-ray telescopes
Alignment
Silicon-strip detectors
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
期刊论文
OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 卷号: 893, 页码: 43-56
作者:
Lei, SJ
;
Li, X
;
Loparco, F
;
Marsella, G
;
Mazziotta, MN
  |  
收藏
  |  
浏览/下载:44/0
  |  
提交时间:2019/07/11
Cosmic-ray detectors
Gamma-ray telescopes
Alignment
Silicon-strip detectors
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:42/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
First charge collection and position-precision data on the medium-resistivity silicon strip detectors before and after neutron irradiation up to 2x10(14) n/cm(2)
期刊论文
iSwitch采集
Nuclear instruments & methods in physics research section a-accelerators spectrometers detectors and associated equipment, 1999, 卷号: 426, 期号: 1, 页码: 38-46
作者:
Li, Z
;
Dezilllie, B
;
Eremin, V
;
Li, CJ
;
Verbitskaya, E
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2019/05/12
Strip detectors
Silicon detectors
Annealing
Simulation
Irradiation
First charge collection and position-precision data on the medium-resistivity silicon strip detectors before and after neutron irradiation up to 2x10(14) n/cm(2)
会议论文
OAI收割
2nd international conference on radiation effects on semiconductor materials, detectors and devices, florence, italy, mar 04-06, 1998
Li Z
;
Dezilllie B
;
Eremin V
;
Li CJ
;
Verbitskaya E
收藏
  |  
浏览/下载:34/0
  |  
提交时间:2010/11/15
strip detectors
silicon detectors
annealing
simulation
irradiation
N-EFF
JUNCTION DETECTORS
RADIATION-DAMAGE
MODELS
First charge collection and position-precision data on the medium-resistivity silicon strip detectors before and after neutron irradiation up to 2x10(14) n/cm(2)
期刊论文
OAI收割
nuclear instruments & methods in physics research section a-accelerators spectrometers detectors and associated equipment, 1999, 卷号: 426, 期号: 1, 页码: 38-46
Li Z
;
Dezilllie B
;
Eremin V
;
Li CJ
;
Verbitskaya E
收藏
  |  
浏览/下载:50/0
  |  
提交时间:2010/08/12
strip detectors
silicon detectors
annealing
simulation
irradiation
JUNCTION DETECTORS
RADIATION-DAMAGE
MODELS
N-EFF