Sensitivity analysis of gravity anomalies and vertical gravity gradient data for bathymetry inversion
期刊论文
OAI收割
MARINE GEOPHYSICAL RESEARCH, 2019, 卷号: 40, 期号: 1, 页码: 87-96
作者:
Wan, Xiaoyun
;
Ran, Jiangjun
;
Jin, Shuanggen
  |  
收藏
  |  
浏览/下载:41/0
  |  
提交时间:2019/05/23
Gravity anomaly
Vertical gravity gradient
Bathymetry inversion
Accuracy requirement
Seafloor topography
Rectification methods comparison for the ASTER GDEM V2 data using the ICESat/GLA14 data in the Lvliang mountains, China
SCI/SSCI论文
OAI收割
2015
作者:
Zhao S. M.
;
Wang, L.
;
Cheng, W. M.
;
Liu, H. J.
;
He, W. C.
收藏
  |  
浏览/下载:45/0
  |  
提交时间:2015/12/09
ASTER GDEM V2 data
ICESat/GLA14 data
Rectification method
GCP data
RMSE
Lvliang Mountains
spatial interpolation methods
digital elevation models
high-accuracy
srtm dem
vertical accuracy
level changes
tandem-x
india
performance
jharkhand
The research of attack angle measurment of projectile with CCD vertical target system
会议论文
OAI收割
2011 international conference on advanced in control engineering and information science, dali, china, august 18-19, 2011
Wang M(王苗)
;
Xu Wei
收藏
  |  
浏览/下载:14/0
  |  
提交时间:2011/12/26
CCD vertical target
attack angle measurement
analysis of accuracy
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE)
会议论文
OAI收割
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.
;
Long-Xu J.
;
Jian-Yue R.
;
Wen-Hua W.
;
Shuang-Li H.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera
because of the influence that gets environmental and artificial etc. factor
the value of static transfer function measured at any time is between unceasing fluctuation
so
make accuracy reduce. To solve this problem
a kind of accurate measurement technique of static transfer function is put forward. First
before carrying out the measure of static quiet of transfer function
the best test point of transfer function of the TDI CCD camera must be determined
it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel
and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image
per 1000 lines of target mark image as a measures sample of static transfer function
exclude because of atmosphere tremble twisted
vague rectangle target mark image
retain 500 distinct and steady target mark image as measure sample set. Then
calculate the static transfer function of each measure sample respectively
take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally
the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923
with before measurement technique comparison
the value of static transfer function has raised 0.02
makes the accuracy of the measure of static transfer function have gotten raising.
Design and test of focusing mechanism of space camera (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Design, Manufacturing, and Testing of Micro- and Nano-Optical Devices and Systems, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Li Y.
;
Li Y.
;
Li Y.
;
Wang H.
;
Wang H.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
According to the focal depth and work environment of a space camera
a focusing mechanism is designed
which consists of precision screw ball transmission and linear bearing guidance and accuracy improving. The dynamic- strike- resistance
adaptability to temperature and vacuum are considered into the reliable design method. Furthermore
the linearity error
the structure stability and the mechanism work situation in high and low temperature are tested. The result is that the linearity error of the mechanism is less than 0.003 mm
and the sway error of vertical way and level way of the mirror is less than 20''. The linearity error of the mechanism and the sway error of the mirror remain unchanged after vibration test. The mechanism can work in the complex space environment. 2010 SPIE.
Influence of spatial temperature distribution on high accuracy interferometric metrology (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Yang H.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Yan F.
收藏
  |  
浏览/下载:26/0
  |  
提交时间:2013/03/25
We calculate the influence of temperature change on the refractive index of air
establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First
a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air
followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer
accompanied by a temperature change random function within each grid. Finally
all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position
angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result
the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus
to realize the high accuracy figure metrology
the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer. 2010 Copyright SPIE - The International Society for Optical Engineering.
Study on dynamic imaging on TDI CCD optical remote sensor of push-broom technology (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Liu L.
;
Ren J.-Y.
;
Liu L.
;
Gao M.-H.
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2013/03/25
A set special detecting system is proposed based on TDICCD push-broom technology applying in dynamic imaging detecting experiment of space optics remote sensor. In the system
In the course of detecting
push-broom movement of the satellite is simulated through using double supporting U structure precision rotary platform with remote sensor by angular speed 0.555/s
regard Nyquist frequency target as detecting aim
within the range of 5 and control precision on steady speed achieves 0.3%
in order to solve matching uncertainty between the CCD pixel and the vertical target strip image when the remote sensor does push-broom
make matching simplify
enhance the measurement result the accuracy. So the tolerance a/n arithmetic progression gap target strip is joined in each group of rectangular vertical group target strip. The remote sensor obtains in vertical
the level and 45 the direction 0 fields of view
0.86 the field of view Nyquist frequency target strip image after detected
a group target strip which can precision matching to TDICCD pixel at least can be obtained through analysis and dealing with 0.86 field of view's target strip image. The experiment not only verifies the detecting system's feasibility but simultaneously verifies whether to have the high quality dynamic imaging quality when TDICCD push-broom technology is adopted on the remote sensor developed. 2010 Copyright SPIE - The International Society for Optical Engineering.