中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共14条,第1-10条 帮助

条数/页: 排序方式:
Pore-existing Lu3Al5O12:Ce ceramic phosphor: An efficient green color converter for laser light source 期刊论文  OAI收割
JOURNAL OF LUMINESCENCE, 2018, 卷号: 197, 页码: 331, 334
作者:  
Zhang, Yunli;  Hu, Song;  Wang, Zhengjuan;  Zhou, Guohong;  Wang, Shiwei
  |  收藏  |  浏览/下载:43/0  |  提交时间:2018/12/28
Tuning the velocity and flux of a low-velocity intense source of cold atomic beam 期刊论文  OAI收割
CHINESE PHYSICS B, 2017, 卷号: 26, 期号: 11, 页码: 113703
作者:  
Chen, Shu;  Li, Ying-Ying;  Yan, Xue-Shu;  Xue, Hong-Bo;  Feng, Yan-Ying
  |  收藏  |  浏览/下载:30/0  |  提交时间:2017/12/19
Proposal for a high brightness gamma-ray source at the SXFEL 期刊论文  OAI收割
NUCLEAR SCIENCE AND TECHNIQUES, 2015, 卷号: 26, 期号: 5, 页码: —
作者:  
Wu, HL;  Chen, JH;  Liu, B;  Wang, D;  Zhao, ZT
收藏  |  浏览/下载:32/0  |  提交时间:2016/03/04
KW-output high beam quality diode laser array source (EI CONFERENCE) 会议论文  OAI收割
2012 International Conference on Optoelectronics and Microelectronics, ICOM 2012, August 23, 2012 - August 25, 2012, Changchun, China
作者:  
Zhang J.;  Wang L.;  Wang L.;  Wang L.;  Liu Y.
收藏  |  浏览/下载:43/0  |  提交时间:2013/03/25
DESIGN OF LOW-TIMING-JITTER, STABLE PICOSECOND OPTICAL-PULSE SOURCE USING AN UNCOOLED GAIN-SWITCHED FABRY-PEROT SEMICONDUCTOR LASER WITH EXTERNAL CONTINUOUS-WAVE LIGHT INJECTION 期刊论文  OAI收割
microwave and optical technology letters, 2011, 卷号: 53, 期号: 9, 页码: 2100-2105
作者:  
Liu, Yuanshan;  Zhang, Jian-Guo
收藏  |  浏览/下载:17/0  |  提交时间:2012/06/29
High gain avalanche photodiode (APD) arrays in flow cytometer opitical system (EI CONFERENCE) 会议论文  OAI收割
2nd International Conference on Multimedia Technology, ICMT 2011, July 26, 2011 - July 28, 2011, Hangzhou, China
作者:  
Chen Y.;  Tang Y.;  Wang C.;  Zhao S.
收藏  |  浏览/下载:52/0  |  提交时间:2013/03/25
Analysis of measuring errors for the visible light phase-shifting point diffraction interferometer (EI CONFERENCE) 会议论文  OAI收割
2010 OSA-IEEE-COS Advances in Optoelectronics and Micro/Nano-Optics, AOM 2010, December 3, 2010 - December 6, 2010, Guangzhou, China
作者:  
Zhang Y.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
In order to improve the measuring accuracy of the visible light phase-shifting point diffraction interferometer (PS/PDI) for the extreme ultraviolet lithography (EUVL) aspheric mirrors  the main measuring errors will be discussed in this paper. At first  the elementary configuration and measuring principle of the visible light phase-shifting point diffraction interferometer are introduced briefly  then the different errors which are possible to affect the measuring result are summed up  the errors include PZT phase-shifting error  detector nonlinearity error  detector quantization error  wavelength instability error and intensity instability error of the laser source  vibration error  air refractivity instability error and so on. Through detailed analysis and simulation  the magnitude of these errors can be obtained. By analysing the reasons which cause these errors and the relationship between these errors and interferometer configuration parameters  some methods are put forward to avoid or restrain these errors accordingly.  
A broadband external cavity tunable InAs/GaAs quantum dot laser by utilizing only the ground state emission 期刊论文  OAI收割
chinese physics b, 2010, 卷号: 19, 期号: 1, 页码: art. no. 018104
作者:  
Jin P
收藏  |  浏览/下载:112/17  |  提交时间:2010/04/04
Monolithic integration of electroabsorption modulators and tunnel injection distributed feedback lasers using quantum well intermixing 期刊论文  OAI收割
chinese physics b, 2010, 卷号: 19, 期号: 12, 页码: article no.124215
Wang Y; Pan JQ; Zhao LJ; Zhu HL; Wang W
收藏  |  浏览/下载:62/1  |  提交时间:2011/07/05
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Song K.-F.;  Li J.-L.;  Zhang W.-L.;  Wang Y.-L.
收藏  |  浏览/下载:40/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.