中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与... [26]
自动化研究所 [2]
力学研究所 [1]
南京天文光学技术研究... [1]
武汉岩土力学研究所 [1]
沈阳自动化研究所 [1]
更多
采集方式
OAI收割 [34]
内容类型
会议论文 [28]
期刊论文 [5]
学位论文 [1]
发表日期
2022 [1]
2018 [2]
2016 [1]
2013 [3]
2012 [1]
2011 [7]
更多
学科主题
天文技术与方法 [1]
流体力学::实验流体... [1]
筛选
浏览/检索结果:
共34条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Metal-based additive manufacturing condition monitoring methods: From measurement to control
期刊论文
OAI收割
ISA TRANSACTIONS, 2022, 卷号: 120
作者:
Lin, Xin
;
Zhu, Kunpeng
;
Fuh, Jerry Ying Hsi
;
Duan, Xianyin
  |  
收藏
  |  
浏览/下载:51/0
  |  
提交时间:2022/05/16
Metal-based additive manufacturing
Condition monitoring
Measurement and control
Machine learning
A novel vibration measurement and active control method for a hinged flexible two-connected piezoelectric plate
期刊论文
OAI收割
Mechanical Systems and Signal Processing, 2018, 卷号: 107, 页码: 357-395
作者:
Liu JG(刘金国)
;
Wang, Xianfeng
;
Qiu ZC(邱志成)
;
Zhang XM(张宪民)
  |  
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2018/03/25
Piezoelectric flexible hinged plate
Active vibration control
Binocular vision measurement
Image processing
RBFNNC algorithm
Decoupling on measurement of the bending and torsional vibration
Feedforward Control for Wind Turbine Load Reduction with Pseudo-LIDAR Measurement
期刊论文
OAI收割
International Journal of Automation and Computing, 2018, 卷号: 15, 期号: 2, 页码: 142-155
作者:
Jie Bao
;
Hong Yue
;
William E. Leithead
;
Ji-Qiang Wang
  |  
收藏
  |  
浏览/下载:13/0
  |  
提交时间:2021/02/23
Wind turbine control
light detection and ranging (LIDAR) measurement
feedforward control
load reduction
gain scheduling
disturbance rejection.
Controls on matrix permeability of shale samples from Longmaxi and Niutitang formations, China
期刊论文
OAI收割
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 卷号: 33, 页码: 599-610
作者:
Qu, Hongyan
;
Pan, Zhejun
;
Peng, Yan
;
Zhou, Fujian
  |  
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2018/06/05
Matrix permeability
Longmaxi and Niutitang shale
Pressure-decay permeability measurement
Geological and geochemical control
Pore-size distribution
Permeability-porosity model
Error analysis of the micro temperature control system (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Measurement, Instrumentation and Automation, ICMIA 2012, September 15, 2012 - September 16, 2012, Guangzhou, China
Han Z.
;
Song K.
收藏
  |  
浏览/下载:48/0
  |  
提交时间:2013/03/25
In order to improve the measurement accuracy of optical detection instruments
temperature control circuits for narrow band-pass filters are given
and the error analysis is applied to temperature control circuits.The principle of a temperature measurement circuit is studied and the method of a driver circuit is described. A variety of influencing factors of temperature control accuracy are discussed. Moreover
for these error factors
improvement measures are given to reduce the nonlinear error. Finally
circuit parameter error is quantified to propose a calculation method for margin of error in a temperature control system. (2013) Trans Tech Publications
Switzerland.
Data normalization of single camera visual measurement network system (EI CONFERENCE)
会议论文
OAI收割
2012 International Conference on Information Technology and Management Innovation, ICITMI 2012, November 10, 2012 - November 11, 2012, Guangzhou, China
作者:
Zhang Y.-C.
;
Zhou J.
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2013/03/25
With the development of visual measurement system
Normalize the measured coordinates into the same world coordinate system
Apply in the three coordinate measuring machine(CMM) to have the simulation experiment
So the data normalization has the advantage of more high precision. (2013) Trans Tech Publications
the visual measurement system of single camera which applied in the imaging theory of optical feature points
then get the global data
the result indicates that the maximum absolute tolerance between the normalization coordinates via the center of point set and the ones measured by CMM directly is 0.058mm
Switzerland.
it has been widespread used in the modern production. Due to the limit of the environment in scene
and achieve the overall measurement
the visual measurement system of single camera could not measure the shield between the measured objects each other. Focus on this problem
But the one between the coordinate repeatedly measured at the position of one network control point is 0.066mm
present a kind of the the knowledge of measurement network based on the visual measurement of single camera
set up the measurement network system via the multi-control points. Measure the optical feature points in every network control point via the visual measurement system of single camera
Visual measurement and control for underwater robots: A survey
会议论文
OAI收割
25th Chinese Control and Decision Conference, Guiyang, China, 2013
作者:
Sun Feihu
;
Yu Junzhi
;
Xu De
收藏
  |  
浏览/下载:100/0
  |  
提交时间:2017/01/23
Visual measurement and control
Underwater robots
Embedded vision
Bio-robotics.
The research of round raster readheads scheme (EI CONFERENCE)
会议论文
OAI收割
3rd international Conference on Manufacturing Science and Engineering, ICMSE 2012, March 27, 2012 - March 29, 2012, Xiamen, China
Cong J.-F.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
The round raster is extensively applied in all kinds of high accuracy angular displacement measurement and control system. With the development of precise mechanotronics measuring instrument
machining center
CNC machine and various precise location testing technology
a higher request is put forward to the accuracy and the function of raster measurement system. In this article it is concluded that double readheads is the most reasonable configuration scheme through tests of single readhead scheme
two readheads and four readheads. (2012) Trans Tech Publications.
The sequence measurement system of the IR camera (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
作者:
Zhang H.-B.
;
Han H.-X.
;
Geng A.-H.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
Currently
the IR cameras are broadly used in the optic-electronic tracking
optic-electronic measuring
fire control and optic-electronic countermeasure field
but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras
the sequence measurement system of the IR camera is designed
and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system
and the precise sequence of the IR camera's output signal has been achieved
the detailed document of the IR camera has been supplied to the continuous image transmission system
image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part
LVDS input interface part
FPGA part
CameraLink output interface part and etc
thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system
and because the image processing card and image memory card always use the CameraLink interface as its input interface style
the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system
the sequence measurement program
the pixel clock modification
the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement program written by the verilog language combining the SignalTap tool on line observation can count the line numbers in one frame
pixel numbers in one line and meanwhile account the line offset and row offset of the image. Aiming at the complex sequence of the IR camera's output signal
the sequence measurement system of the IR camera accurately measures the sequence of the project applied camera
supplies the detailed sequence document to the continuous system such as image processing system and image transmission system and gives out the concrete parameters of the fval
lval
pixclk
line offset and row offset. The experiment shows that the sequence measurement system of the IR camera can get the precise sequence measurement result and works stably
laying foundation for the continuous system. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
The research on adaptive measurement of angular acceleration for photoelectric servo turntable (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Mechatronic Science, Electric Engineering and Computer, MEC 2011, August 19, 2011 - August 22, 2011, Jilin, China
作者:
Guo J.
;
Chen J.
;
Guo J.
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2013/03/25
The paper proposes a new measurement method of angular acceleration for photoelectric servo turntable. Piezoelectric angular acceleration sensor is used to measure angular acceleration directly
Adaptive FIR filter based on LMS algorithm is established on DSP
by which angular acceleration signal can be filtered and corrected errors adaptively
then angular acceleration signals can be measured adaptively. This method avoids measurement errors and calculation noise by computing angular acceleration indirectly
thus improving measurement precision and making measurement results better than traditional methods. The gotten angular acceleration can be sent to servo control mechanism as feed forward control signals to improve control effects of servo turntable significantly. 2011 IEEE.