中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [4]
金属研究所 [3]
心理研究所 [2]
力学研究所 [1]
武汉岩土力学研究所 [1]
采集方式
OAI收割 [11]
内容类型
期刊论文 [6]
会议论文 [5]
发表日期
2024 [1]
2022 [1]
2018 [3]
2017 [2]
2010 [2]
2007 [1]
更多
学科主题
Materials ... [1]
Metallurgy... [1]
Nanoscienc... [1]
筛选
浏览/检索结果:
共11条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Redundancy effect of initial enactment encoding and subsequent testing on memory enhancement: Insights from an electrophysiological study
期刊论文
OAI收割
BRAIN RESEARCH, 2024, 卷号: 1836, 页码: 9
作者:
Cui, Xiaoyu
;
Lu, Jing
;
Liu, Yi
;
Li, Juan
;
Zheng, Zhiwei
  |  
收藏
  |  
浏览/下载:12/0
  |  
提交时间:2024/06/15
Testing effect
Enactment
Event-related potentials
Old/new effect
Recollection
Toward an understanding of dwell fatigue damage mechanism of bimodal Ti-6Al-4V alloys
期刊论文
OAI收割
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2022, 卷号: 108, 页码: 244-255
作者:
Zeng, L. R.
;
Lei, L. M.
;
Luo, X. M.
;
Zhang, G. P.
  |  
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2022/07/01
Dwell effect
Fatigue damage
Stress relaxation
Volume fraction of primary alpha phase
Quasi-in-situ testing
The high cycle fatigue, deformation and fracture of compacted graphite iron: Influence of temperature
期刊论文
OAI收割
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2018, 卷号: 724, 页码: 606-615
作者:
Zou, CL
;
Pang, JC
;
Zhang, MX
;
Qiu, Y
;
Li, SX
  |  
收藏
  |  
浏览/下载:38/0
  |  
提交时间:2018/12/25
Compacted graphite iron
Testing temperature
High-cycle fatigue property
Oxidation effect
Dynamic strain ageing
The high cycle fatigue, deformation and fracture of compacted graphite iron: Influence of temperature
期刊论文
OAI收割
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2018, 卷号: 724, 页码: 606-615
作者:
Zou, C. L.
;
Pang, J. C.
;
Zhang, M. X.
;
Qiu, Y.
;
Li, S. X.
  |  
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2021/02/02
Compacted graphite iron
Testing temperature
High-cycle fatigue property
Oxidation effect
Dynamic strain ageing
A robust and powerful two-step testing procedure for local ancestry adjusted allelic association analysis in admixed populations
期刊论文
OAI收割
GENETIC EPIDEMIOLOGY, 2018, 卷号: 42, 期号: 3, 页码: 288-302
作者:
Duan, Qing
;
Xu, Zheng
;
Raffield, Laura M.
;
Chang, Suhua
;
Wu, Di
  |  
收藏
  |  
浏览/下载:66/0
  |  
提交时间:2018/05/28
Admixed Populations
Association Analysis
Effect Heterogeneity
Genome-wide Association Studies
Gwas
Local Ancestry
Population Stratification
Testing Procedure
Evaluation and reduction of the end friction effect in true triaxial tests on hard rocks
期刊论文
OAI收割
INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2017, 卷号: 97, 页码: 144-148
作者:
Peng, Shuai
;
Feng, Xia-Ting
;
Zhang, Xiwei
;
Yang, Chengxiang
;
Kong, Rui
  |  
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2018/06/05
True triaxial testing
Hard rock
End friction effect
Antifriction
Effect
Stearic acid
Application of acoustic emission, anisotropy of acoustic velocity and palaeomagnetie technology to determine in-situ stress in tight sands
会议论文
OAI收割
Jeju, Korea, Republic of, May 10, 2017 - May 13, 2017
作者:
Shi X
;
Yang L(杨柳)
;
Han QR
  |  
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2018/11/08
Acoustic emission testing
Acoustic wave velocity
Acoustic wave velocity measurement
Anisotropy
Core drilling
Core samples
Hydraulic fracturing
Infill drilling
Magnetization
Rock mechanics
Rocks
Sand consolidation
Stress measurement
Stresses
Acoustic velocity methods
Confining pressures
Geographic orientations
In
situ stress measurement
Kaiser effect
Non destructive testing
Ordos basin , China
Remanent magnetization
Temperature gradients effect on surface test with high precise interferometer (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Gu Y.-Q.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
In high precise surface testing
temperature stability and uniformity are of paramount importance to the high accuracy of test results. Micro-temperature variation and temperature gradients not only cause the change of the air refractive index and lead to the optical path variation in interferometer cavity
but also result in deformation of the tested surface itself
which always brings about errors to the test results. Temperature effects on the interferometer cavity and the tested surface are analyzed from the axial and radial directions in this letter. Temperature model of the interferometer cavity and the tested lens are established and quantitative calculations and diagram of test results versus temperature and lens dimension are provided. It shows that temperature gradients effect increase with the length of the interferometer and the dimension of the tested lens. The interferometer cavity is mainly affected by radial temperature gradients while the tested lens is mainly affected by the axial temperature gradients. 2010 Copyright SPIE - The International Society for Optical Engineering.
Influence of spatial temperature distribution on high accuracy interferometric metrology (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Yang H.
;
Zhang J.
;
Zhang J.
;
Zhang J.
;
Yan F.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
We calculate the influence of temperature change on the refractive index of air
establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First
a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air
followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer
accompanied by a temperature change random function within each grid. Finally
all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position
angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result
the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus
to realize the high accuracy figure metrology
the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer. 2010 Copyright SPIE - The International Society for Optical Engineering.
Mid-frequency surface error test with a Foucault apparatus (EI CONFERENCE)
会议论文
OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, July 8, 2007 - July 12, 2007, Chengdu, China
作者:
Li J.
;
Li J.
;
Xuan B.
;
Li J.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
Testing of mid-frequency surface error is of the first importance for fast optics
especially for large aperture aspherics. Foucault test plays a dominant role for surface error inspection before the digital interferometer age
but it seems to have faded out these days because no quantitative results turn out. However
an interferometer with high resolution CCDs is either unavailable or unaccessible in the process of manufacture. As its advantages are realized and recognized for the second time
Foucault test is going back to the stage again. A new theory of calculating the contrast of the shadow pattern of Foucault test is put forward in this paper and some modifications are discussed upon the analyses of the limitation of traditional Foucault apparatus. A paraboloidal mirror was fabricated and tested by the modified Foucault apparatus whose effect has been proved to be great. The methods of controlling mid-frequency error are described in the other paper at this conference- "Multi-mode combine manufacturing technology for large aperture aspheric mirrors"1.