中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [4]
西安光学精密机械研究... [2]
物理研究所 [1]
金属研究所 [1]
化学研究所 [1]
生态环境研究中心 [1]
更多
采集方式
OAI收割 [10]
iSwitch采集 [1]
内容类型
期刊论文 [6]
会议论文 [5]
发表日期
2023 [2]
2018 [1]
2016 [1]
2015 [2]
2011 [2]
2010 [2]
更多
学科主题
筛选
浏览/检索结果:
共11条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Development of space-resolved EUV spectrometers working at 5-138 Å for profile observation of high-Z impurity ions in EAST plasma
期刊论文
OAI收割
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 卷号: 1057
作者:
Cheng, Yunxin
;
Zhang, Ling
;
Morita, Shigeru
;
Hu, Ailan
;
Xu, Zong
  |  
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2023/11/17
EAST tokamak
Impurity diagnostics
Extreme ultraviolet (EUV) spectrometer
CMOS detector
Middle and near ultraviolet spectrograph of the Scientific Experimental system in Near SpacE (SENSE)
期刊论文
OAI收割
Earth and Planetary Physics, 2023, 卷号: 7, 期号: 6, 页码: 655-664
作者:
Sun, Xin
;
Shi, Dalian
;
Chen, Zhen
;
Li, Ran
;
Cao, Weiwei
  |  
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2023/12/06
ultraviolet spectrograph
radiation background
imaging grating
intensified detector
low-pressure discharge
spectral calibration
ZnO Ultraviolet Photodetector Modified with Graphdiyne
期刊论文
OAI收割
ACTA PHYSICO-CHIMICA SINICA, 2018, 卷号: 34, 期号: 9, 页码: 1088-1094
作者:
Huang Zhijuan
;
Yu Zhinong
;
Li Yan
;
Wang Jizheng
  |  
收藏
  |  
浏览/下载:33/0
  |  
提交时间:2019/04/09
Graphdiyne
Zinc Oxide
Ultraviolet Detector
Responsivity
Detectivity
Highly sensitive and ultrafast deep uv photodetector based on a β-ga2o3 nanowire network grown by cvd
期刊论文
iSwitch采集
Journal of physics d: applied physics, 2016, 卷号: 49, 期号: 42
作者:
Du,Jianyu
;
Xing,Jie
;
Ge,Chen
;
Liu,Hao
;
Liu,Pengyu
收藏
  |  
浏览/下载:45/0
  |  
提交时间:2019/05/09
β-ga2o3
Nanowire
Solar-blind ultraviolet detector
Improved Method for Real-Time Fluence Monitoring in UV Reactors
期刊论文
OAI收割
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2015, 卷号: 141, 期号: 4, 页码: -
作者:
Li, Mengkai
;
Qiang, Zhimin
;
Bolton, James R.
;
Li, Wentao
;
Wang, Chen
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2016/03/11
Ultraviolet (UV) disinfection
Fluence
Real-time monitoring
Microfluorescent silica detector
Operation and maintenance
High performance ultraviolet detector based on SrTiO3/TiO2 heterostructure fabricated by two steps in situ hydrothermal method
期刊论文
OAI收割
JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 卷号: 650, 页码: 97-101
Jing, Fuyi
;
Zhang, Dezhong
;
Li, Feng
;
Zhou, Jingran
;
Sun, Dongming
;
Ruan, Shengping
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2016/04/21
Ultraviolet detector
Heterostructure
High responsivity
Hydrothermal
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
Research on UV detector technology and application in MAWS
会议论文
OAI收割
international symposium on photoelectronic detection and imaging 2011: advances in imaging detectors and applications, beijing, china, may 24, 2011 - may 26, 2014
YaoDa-Wei
;
HaoWei
;
YangXiao-Jun
;
TianYan
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2012/07/09
Ultraviolet detector
Sensitive
Ultraviolet radiation
Ultraviolet warning system
Target imaging
Analysis of measuring errors for the visible light phase-shifting point diffraction interferometer (EI CONFERENCE)
会议论文
OAI收割
2010 OSA-IEEE-COS Advances in Optoelectronics and Micro/Nano-Optics, AOM 2010, December 3, 2010 - December 6, 2010, Guangzhou, China
作者:
Zhang Y.
收藏
  |  
浏览/下载:13/0
  |  
提交时间:2013/03/25
In order to improve the measuring accuracy of the visible light phase-shifting point diffraction interferometer (PS/PDI) for the extreme ultraviolet lithography (EUVL) aspheric mirrors
the main measuring errors will be discussed in this paper. At first
the elementary configuration and measuring principle of the visible light phase-shifting point diffraction interferometer are introduced briefly
then the different errors which are possible to affect the measuring result are summed up
the errors include PZT phase-shifting error
detector nonlinearity error
detector quantization error
wavelength instability error and intensity instability error of the laser source
vibration error
air refractivity instability error and so on. Through detailed analysis and simulation
the magnitude of these errors can be obtained. By analysing the reasons which cause these errors and the relationship between these errors and interferometer configuration parameters
some methods are put forward to avoid or restrain these errors accordingly.
Linearity measurement for image-intensified CCD (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Zhang L.
;
Zhao Y.
;
Zhao Y.
;
Zhao Y.
;
Yan F.
收藏
  |  
浏览/下载:31/0
  |  
提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)
technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed
and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system
and calibration of the filters' transmittance in different working positions has been done. Meanwhile
to assure the uniform of the received radiation on the target of the detector at any test points
an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization
the attenuation film with transmission
integrating sphere
optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument
the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.