中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [5]
物理研究所 [2]
上海光学精密机械研究... [2]
西安光学精密机械研究... [1]
近代物理研究所 [1]
采集方式
OAI收割 [10]
iSwitch采集 [1]
内容类型
会议论文 [5]
期刊论文 [5]
学位论文 [1]
发表日期
2014 [1]
2013 [3]
2011 [1]
2010 [1]
2009 [2]
2008 [1]
更多
学科主题
光学工程 [1]
筛选
浏览/检索结果:
共11条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
Exact Analytical Solution for the Mutual Compensation of Astigmatism Using Curved Mirrors in a Folded Resonator Laser
期刊论文
OAI收割
ieee photonics journal, 2014, 卷号: 6, 期号: 6
作者:
Wen Qiao
;
Liang Guowen
;
Zhang Xiaojun
;
Liang Zongsen
;
Wang Yonggang
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2015/03/20
Solid-state lasers
optical resonators
laser cavity resonators
astigmatism compensation
phase compensation
Nanopillar array with a λ/11 diameter fabricated by a kind of visible cw laser direct lithography system
期刊论文
iSwitch采集
Nanoscale research letters, 2013, 卷号: 8, 期号: 1
作者:
Zhang,Chen
;
Wang,Kaige
;
Bai,Jintao
;
Wang,Shuang
;
Zhao,Wei
收藏
  |  
浏览/下载:42/0
  |  
提交时间:2019/05/09
Nanopillar
Diffraction limit
Lithography
Coma
Astigmatism
Advanced astigmatism-corrected tandem Wadsworth mounting for small-scale spectral broadband imaging spectrometer (EI CONFERENCE)
会议论文
OAI收割
作者:
Lin G.-Y.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
Tandem gratings of double-dispersion mount make it possible to design an imaging spectrometer for the weak light observation with high spatial resolution
high spectral resolution
and high optical transmission efficiency. The traditional tandem Wadsworth mounting is originally designed to match the coaxial telescope and large-scale imaging spectrometer. When it is used to connect the off-axis telescope such as off-axis parabolic mirror
it presents lower imaging quality than to connect the coaxial telescope. It may also introduce interference among the detector and the optical elements as it is applied to the short focal length and small-scale spectrometer in a close volume by satellite. An advanced tandem Wadsworth mounting has been investigated to deal with the situation. The Wadsworth astigmatism-corrected mounting condition for which is expressed as the distance between the second concave grating and the imaging plane is calculated. Then the optimum arrangement for the first plane grating and the second concave grating
which make the anterior Wadsworth condition fulfilling each wavelength
is analyzed by the geometric and first order differential calculation. These two arrangements comprise the advanced Wadsworth mounting condition. The spectral resolution has also been calculated by these conditions. An example designed by the optimum theory proves that the advanced tandem Wadsworth mounting performs excellently in spectral broadband. 2012 Optical Society of America.
Nanopillar array with a lambda/11 diameter fabricated by a kind of visible CW laser direct lithography system
期刊论文
OAI收割
NANOSCALE RESEARCH LETTERS, 2013, 卷号: 8
Zhang, C
;
Wang, KG
;
Bai, JT
;
Wang, S
;
Zhao, W
;
Yang, F
;
Gu, CZ
;
Wang, GR
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2014/01/16
Nanopillar
Diffraction limit
Lithography
Coma
Astigmatism
Study on spectrograph for ionosphere: A broadband imaging instrument prototype for far-ultraviolet (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications, May 24, 2011 - May 26, 2011, Beijing, China
作者:
Wang S.-R.
;
Lin G.-Y.
;
Yu L.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
Current research on space-based exploration for the ionosphere needs more advanced technologies. Because the spectral signals in the ionosphere distributing basically in the far-ultraviolet waveband are very weak. Usual spectrometer structures and detectors such as CCD can't receive enough information. Based on this principle of atmospheric sounding
the imaging spectrometer prototype for ionosphere detection application was designed to solve the problem. This prototype consists of the telescope and the imaging spectrometer. The simple structure and small number of mirrors can help higher transmission efficiency be achieved and weak signals detection be implemented. The telescope is an off-axis parabolic mirror and the spectrometer is a modified Czerny-Turner spectral imaging system. Modified Czerny-Turner spectrometer contains a spherical mirror
a fixed plane grating and a toroidal mirror. By adjusting the incident angle to the collimating mirror and using toroidal mirror
coma and astigmatism were corrected well. We also optimize distances between the grating to the focusing mirror and the focusing mirror to the image plane to improve disadvantages of traditional Czerny-Turner structure. Designed results demonstrate that aberrations are substantially corrected
and high image quality can be obtained in broad waveband. The photon counting Wedge-Strip-Anode detector with micro-channel planes as the receiving plane is accepted for the instrument prototype. The other photon counting 2-D detector responding well for weak light such as Cross-Delay line detector and MAMA detector can also be used for detection. The calibration and performances testing system is made of a vacuum system
a deuterium lamp
a monochrometer and the instrument prototype. Results obtained from the experiment show that the spectral resolution is 2.4 nm and the spatial resolution is 80 m. The other calibration experiments are running. The technology of the spectrometer prototype is important for the research and applications of ionosphere remote sensing. 2011 SPIE.
A new method for comparing Zernike circular polynomials with Zernike annular polynomials in annular pupils (EI CONFERENCE)
会议论文
OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Jing S.
;
Dongmei M.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
To compare the difference between Zernike annular polynomial and Zernike circular polynomial
an approximate mathematic relationship between Zernike annular polynomial coefficients and SEIDEL coefficients is proposed. A new method is applied in comparing experiment. For real interferometric data of annular wave front
the SEIDEL aberration calculated in different ways is removed from the original wave front. Residual astigmatism aberration in annular polynomial way is close to zero
but defocus and sphere aberration are 0.002709
-0.00182. The residual SEIDEL using annular polynomial is least. Data used in comparison shows that Zernike annular polynomial is more accurate and meaningful for the decomposition of aberrations and the calculation of Seidel aberrations in annular pupil. The calculation in astigmatism aberration is most accurate and those in defocus and sphere aberration are least accurate
when the first 9 terms are used in approximate solving SEIDEL. More coefficients are needed to obtain the real SEIDEL. 2010 IEEE.
Design of aspherical surfaces for panoramic imagers using multipopulations genetic algorithm (EI CONFERENCE)
会议论文
OAI收割
4th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Advanced Optical Manufacturing Technologies, November 19, 2008 - November 21, 2008, Chengdu, China
作者:
Jin C.-S.
;
Wang L.-P.
;
Liang Z.-Z.
收藏
  |  
浏览/下载:29/0
  |  
提交时间:2013/03/25
A design method of aspherical surface for panoramic imaging system with two mirrors using multi-populations genetic algorithms is proposed. Astigmatism induced by mirrors may significantly compromise image resolution. To solve this problem
we induced algebraic expression of astigmatism in panoramic imager based on generalized Coddington equation and theory of geometric optics. Then
we propose an optimization process for mirror profile design to eliminate astigmatism and provide purposely-designed projection formula with aid of MPGA. A series of polynomial expressions of aspherical surfaces are obtained and procedures of the design are presented. In order to facilitate ray tracing and aberration calculation
even asphere surface model is obtained by using of hybrid schemes combining MPGA and damped least squares. Finally
a prototype of the catadioptric panoramic imager has been developed and panoramic ring image is obtained. 2009 SPIE.
Even aberration measurement of lithographic projection system based on optimized phase-shifting marks
期刊论文
OAI收割
microelectron. eng., 2009, 卷号: 86, 期号: 1, 页码: 78, 82
Yuan Qiongyan
;
王向朝
;
Qiu Zicheng
;
Wang Fan
;
马明英
收藏
  |  
浏览/下载:1101/181
  |  
提交时间:2009/09/18
Lithography
Projection optics
Spherical aberration
Astigmatism
Zernike coefficients
The effect on tolerance distributing of an off-axis three mirror anastigmatic optical system with wavefront coding technology (EI CONFERENCE)
会议论文
OAI收割
Optical System Alignment and Tolerancing II, August 10, 2008 - August 11, 2008, San Diego, CA, United states
作者:
Yan F.
;
Zhang X.-J.
;
Yan F.
收藏
  |  
浏览/下载:35/0
  |  
提交时间:2013/03/25
The wavefront coding technology is known as a system-level technology which can extend the depth of focus of optical system by innovative optical design and image restoration. This technology can control misfocus related aberrations including misfocus
astigmatism
and Petzval curvature
temperature-related misfocus in digital imaging systems. It can also help optical system tolerate more residual error in optical manufacturing and alignment besides misfocus. The brief introduction of wavefront coding technology and the wavefront coded TMA system under research is presented respectively in part 1 and part 2. The "MTF similarity" is defined to describe the relationship among MTF at different position or different fields in the third part. It is also shown in this part that the MTF similarity of wavefront coded system is much higher than the normal system within a large range. In part 4 comparison between the origin system and the new system with wavefront coding technology is provided after multiple errors are introduced
from which it can be observed that the system with wavefront coding technology can tolerate much bigger error than origin system. The error tolerance is re-distributed according to a new criterion based on MTF similarity. If the MTF similarity is less than a certain value
it can be regarded that the system can tolerate the residual error. The new error tolerance is displayed and it is shown that the wavefront coding technology can also loosen the error distributing besides extended the depth of focus.
Collimation test of a corrected laser diode beam using lateral shearing interferometer
期刊论文
OAI收割
OPTICS COMMUNICATIONS, 2007, 卷号: 274, 页码: 412-416
作者:
Wang, Yi
;
Zhai, Hongchen
;
Jutamulia, Suganda
;
Mu, Guoguang
  |  
收藏
  |  
浏览/下载:12/0
  |  
提交时间:2018/05/31
laser diode
corrected beam
beam collimation
astigmatism
lateral shearing interferometer