中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
首页
机构
成果
学者
登录
注册
登陆
×
验证码:
换一张
忘记密码?
记住我
×
校外用户登录
CAS IR Grid
机构
长春光学精密机械与物... [8]
数学与系统科学研究院 [2]
采集方式
OAI收割 [10]
内容类型
会议论文 [8]
期刊论文 [2]
发表日期
2021 [1]
2011 [4]
2010 [1]
2009 [1]
2008 [2]
2004 [1]
更多
学科主题
筛选
浏览/检索结果:
共10条,第1-10条
帮助
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
题名升序
题名降序
提交时间升序
提交时间降序
作者升序
作者降序
发表日期升序
发表日期降序
A model-averaging treatment of multiple instruments in Poisson models with errors
期刊论文
OAI收割
CANADIAN JOURNAL OF STATISTICS-REVUE CANADIENNE DE STATISTIQUE, 2021, 页码: 26
作者:
Zhang, Xiaomeng
;
Zhang, Xinyu
;
Ma, Yanyuan
  |  
收藏
  |  
浏览/下载:50/0
  |  
提交时间:2022/04/02
Count response
error in variable
instrumental variable
measurement error
minimum risk
model averaging
Poisson regression
prediction optimality
Design of thermostat system based on Proteus simulation software (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electronic and Mechanical Engineering and Information Technology, EMEIT 2011, August 12, 2011 - August 14, 2011, Harbin, China
Han Z.
;
Song K.
收藏
  |  
浏览/下载:39/0
  |  
提交时间:2013/03/25
In order to solve the problem of precise temperature control
the thermoelectric cooler (TEC) principle widely used is analyzed for the design of the whole control process and selection of control parameters
and then accurate simulation model of the TEC is established in Proteus simulation software. Moreover
combined with the traditional circuit simulation model
the temperature control loop is designed
and the response characteristics of the system are tested using an input signal similar to the unit-step function to achieve the precise temperature control. Simulation results show that the proposed control circuits can precisely convert error signal to output voltage sent to TEC model
and TEC model behaves approximately like a two-pole system. The first pole starts at 20mHz and a second pole at 1Hz. 2011 IEEE.
Distribution of gyroscope accuracy parameters for E-O stabilization platform (EI CONFERENCE)
会议论文
OAI收割
2011 International Conference on Electric Information and Control Engineering, ICEICE 2011, April 15, 2011 - April 17, 2011, Wuhan, China
作者:
Zhang X.
;
Zhang X.
;
Zhang X.
;
Jiang H.
收藏
  |  
浏览/下载:28/0
  |  
提交时间:2013/03/25
E-O stabilization platform performance is partly decided by gyroscope precision
so it is important to choose a gyroscope with proper accuracy for an E-O stabilization platform. Based on the method of using a gyroscope in practice
gyroscope error model is established. With the gyroscope error model gyroscope accuracy parameters
that is bias repeatability
bias stability
scale factor
scale factor nonlinearity
output noise and bandwidth
are separately analyzed. According to the concretely required performance indices for an E-O platform
means of distribution of gyroscope accuracy parameters is proposed. A MEMS gyroscope is tested to get the parameters. Bias stability of the gyroscope is 0.08 /s while the bandwidth is 60 Hz. Output noise both at zero input and at nonzero input is analyzed by means of PSD to get the result that nonzero output noise is higher than zero output noise. Frequency response result of the gyroscope is dealt by means of correlation analysis. With all the tested result and the method of distribution of gyroscope accuracy parameters
it is clear that how the gyroscope errors works in an E-O servo system. The principle of distribution of gyroscope accuracy parameters is helpful for choosing appropriate gyroscope for an E-O platform. 2011 IEEE.
Applying observer feedback in motor control (EI CONFERENCE)
会议论文
OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
Huan Z.-Y.
;
Li H.-W.
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2013/03/25
When the speed is low or the encoder has a low precision
speed measured by backward difference method has obvious truncation error. This will arise ripple in the control system speed response. Speed filtering can decrease the ripple
but it's not good enough
and it also induces lag. A speed feedback method based on all-state observer was introduced to improve the speed feedback performance. Experiment results show that
compared to filtering method
the control system performance is improved.
Study of experimental design and Response Surface method for surrogate model of computational simulation (EI CONFERENCE)
会议论文
OAI收割
2nd Annual Conference on Electrical and Control Engineering, ICECE 2011, September 16, 2011 - September 18, 2011, Yichang, China
Xi R.
;
Jia H.
;
Xiao Q.
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2013/03/25
While the high-precision simulation is widely used in science and technology
Design of Experiment (DOE) based on Response Surface (RS) method can be employed in surrogate model to reduce the cost and error. In order to illustrate the relationship between parameters and response features
several DOE methods and Response Surface (RS) method are studied. The author used polynomial regression and RBF neural network based on orthogonal array to build a rocket aerodynamic discipline surrogate model respectively which proved their feasibility. From the results of the test case
conclusion is drawn that characteristic as well as acclimatization of DOE methods and different approximation should be considered for different issues
so the factors of cost and accuracy could reach a balance synthetically. 2011 IEEE.
Research of active supporting technology based on 400mm thin mirror (EI CONFERENCE)
会议论文
OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, April 26, 2010 - April 29, 2010, Dalian, China
作者:
Liu X.-Y.
;
Wang J.-L.
;
Wang J.-L.
;
Liu X.-Y.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
Using a spherical mirror of 400mm diameter and 12mm thickness
active supporting technology of thin mirror is researched. The axial support of the mirror is composed of 12 active supports and 3 fixed supports. The force actuator
which is composed of displacement actuator and force sensor
is installed in the active support. The mirror surface is tested by Zygo interferometer. For calibration
each actuator exerts unit force alone
and the surface variation is tested and taken as the response function of the actuator. The response functions of all actuators compose the stiffness matrix. Then the stiffness matrix is used by damped least square method to determine the correction force of each active support. In order to analyze the correction capability of the active supports
14 Zernike modes of the mirror surface are generated and tested respectively
and 7 modes are selected for correction. Initially
the RMS error of mirror surface is 1.16 I( =0.6328nm)when all actuators exert the same force. After 5 iterations
the RMS error of mirror surface is reduced to 0.13
close to the original surface quality. 2010 Copyright SPIE - The International Society for Optical Engineering.
Micro-motion exposure method based on PZT piezoelectric ceramics (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Material and Device Technology for Sensors, June 17, 2009 - June 19, 2009, Beijing, China
作者:
Meng Z.
;
Meng Z.
收藏
  |  
浏览/下载:102/0
  |  
提交时间:2013/03/25
There mainly is laser digital photofinishing technique and digital photofinishing technique based on LCD consisting of TFT and LCOS in the digital photofinishing field at the present time. The former have a good many merit such as wide color gamut
high processing rate
large output size and high brightness
but his cost is very high
his maintain technique being comparatively complex
that result in difficult use for people. The utilization ratio of the latter is low because of lower resolution and lower aperture ratio for LCD
but the digital photofinishing based on LCD have lower cost and higher utilization ration
being suitable for people's current standard of living. Considering above mentioned problem
a micro-motion exposure method based on PZT piezoelectric ceramics used in digital image photofinishing is presented. The two-dimension micro-motion exposure system consisting of PZT piezoelectric ceramics
LCD panel
polarizing film and spring strip is designed. By means of PZT piezoelectric ceramics the LCD panel is removed about the one half of the pixel size of the LCD panel for four times from the original place
at the same time imaging system is exposed four times at the printing paper. The software is used to control the time synchronization
the exposure time and motion range of the LCD panel. The system has advantages such as shorter response time than 0.1seconds
lesser motion error than 0.01 microns
high stability and repeatability. Experimental results show that the proposed micro-motion exposure method improve the picture brightness and enlarge output size
at the meantime reducing the cost of the system. 2009 SPIE.
Study of adaptive inverse control to stale platform (EI CONFERENCE)
会议论文
OAI收割
International Conference on Computer Science and Software Engineering, CSSE 2008, December 12, 2008 - December 14, 2008, Wuhan, Hubei, China
作者:
Li Y.
;
Li Y.
;
Li Y.
;
Li Y.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
Stable platform is a complicated nonlinear system. The common PID control can not meet the requirement of high precision and fast response. The adaptive inverse control was introduced in the system of stable platform. Based on it
the system utilize its character of open circle to improve system capability. In the model building to object model and object inverse model
the NARX network is used. The algorithm uses the least square method instead of least square(LMS) to identify the parameters and design the control. The simulation results show several advantages of this control strategy
such as sensitive response
non-overshoot
good anti-disturbance
and minimal stable error
and showed dynamic/static performance was superior to those of conventional PID method. 2008 IEEE.
UV-VUV spectral irradiance responsivity calibration for space remote sensing spectroradiometer (EI CONFERENCE)
会议论文
OAI收割
Advanced Materials and Devices for Sensing and Imaging III, November 12, 2007 - November 14, 2007, Beijing, China
作者:
Yu H.
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2013/03/25
In order to overcome the irradiance responsivity calibration troubles caused by the weak response of most spectral radiometers in ultraviolet band and poor ratio of signal to noise
and to meet special calibration condition for some remote sensing spectroradiometers in space
a spectral irradiance responsivity calibration unit based on parallel light illumination mode is established
it is composed of a 150W deuterium lamp and a spherical mirror. The calibration unit gets the output standard value of spectral irradiance by irradiance transfer
this way avoids the spectral reflectance measurement difficulty of the spherical mirror. A flight spectral radiometer model used for space remote sense was calibrated in range from 160nm to 300nm
the calibration error of spectral irradiance responsivity is 4.7%. Some factors which contribute to calibration uncertainties are discussed.
Empirical likelihood-based dimension reduction inference for linear error-in-responses models with validation study
期刊论文
OAI收割
SCIENCE IN CHINA SERIES A-MATHEMATICS, 2004, 卷号: 47, 期号: 6, 页码: 921-939
作者:
Wang, QH
;
Wolfgang, H
  |  
收藏
  |  
浏览/下载:11/0
  |  
提交时间:2018/07/30
confidence intervals
error-in-response
validation data