Rapid One-Tube RPA-CRISPR/Cas12 Detection Platform for Methicillin-Resistant Staphylococcus aureus
期刊论文
OAI收割
DIAGNOSTICS, 2022, 卷号: 12
作者:
Li, Yanan
;
Shi, Zhonglin
;
Hu, Anzhong
;
Cui, Junsheng
;
Yang, Ke
  |  
收藏
  |  
浏览/下载:63/0
  |  
提交时间:2022/05/16
methicillin-resistant Staphylococcus aureus
mecA gene
RPA-CRISPR/Cas12a
one-tube
POCT
Subcooled water flow boiling heat transfer in screw cooling tubes under one-sided heating conditions
期刊论文
OAI收割
APPLIED THERMAL ENGINEERING, 2017, 卷号: 113, 期号: 无, 页码: 621-631
作者:
Liu, P.
;
Peng, X. B.
;
Song, Y. T.
;
Mao, X.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2018/05/02
Screw Tube
Divertor
High Heat Flux Removal
Subcooled Flow Boiling
Enhancement Of Heat Transfer
One-sided Heating
Analysis of polymorphisms of genes associated with folate-mediated one-carbon metabolism and neural tube defects in Chinese Han Population
期刊论文
OAI收割
BIRTH DEFECTS RESEARCH PART A-CLINICAL AND MOLECULAR TERATOLOGY, 2016, 卷号: 106, 期号: 4, 页码: 232-239
作者:
Piao, Wei
;
Guo, Jin
;
Bao, Yihua
;
Wang, Fang
;
Zhang, Ting
收藏
  |  
浏览/下载:30/0
  |  
提交时间:2016/07/14
neural tube defects
single nucleotide polymorphisms
SARDH
folate mediated one-carbon metabolism
Chinese Han population
1D-KBA microscope using double-periodic multilayer (EI CONFERENCE)
会议论文
OAI收割
Advances in X-Ray/EUV Optics and Components IV, August 3, 2009 - August 5, 2009, San Diego, CA, United states
作者:
Wang Z.
;
Wang X.
;
Wang X.
;
Wang X.
;
Wang Z.
收藏
  |  
浏览/下载:11/0
  |  
提交时间:2013/03/25
To study the action of shock wave in CH target
one-dimensional grazing incidence KBA microscope for 4.75keV energy was set up. Because of strong absorption in air
4.75keV energy microscope can just work in vacuum. Accordingly
the alignment and assemblage will be very complicated and difficult. A special multilayer method
using double periodic multilayer
was proposed to solve this problem. This multilayer has high reflectivity not only for 4.75keV X-rays but also for 8keV X-rays at the same grazing incidence angle. It means 1D-KBA microscope has the same light trace for different working energies. Therefore
we can implement the alignment and assembly of 4.75keV system by the help of 8keV X-rays. Because 8keV X-rays is very easy produced by X-ray tube and has strong transmittability in air
the alignment and assemblage process became relatively easy. By now
we have finished the alignment experiment at 8keV and obtained imaging results. The performance is about 2-3m resolution in 250m field of view. It is coincide with the calculation. 2009 SPIE.
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE)
会议论文
OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:
Song K.-F.
;
Li J.-L.
;
Zhang W.-L.
;
Wang Y.-L.
收藏
  |  
浏览/下载:37/0
  |  
提交时间:2013/03/25
In the device
a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source
and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system
so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least
the sample fluorescence through the integrating sphere and come to the grating monochromator
The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device
SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process
signal-to-noise ratio(SNR) will be improved
also adjust delay time
ampling frequency and sampling number arbitrarily. By testing
the sensitivity is 10-12mol/L(substance marked by Eu3+)
examination repeat is &le2.5%
examination linearity is from 10 -8mol/L to 10-12mol/L
correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody
and solve the tumor
genetic variation
the virus protein detection. 2009 SPIE.