中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共5条,第1-5条 帮助

条数/页: 排序方式:
Rapid One-Tube RPA-CRISPR/Cas12 Detection Platform for Methicillin-Resistant Staphylococcus aureus 期刊论文  OAI收割
DIAGNOSTICS, 2022, 卷号: 12
作者:  
Li, Yanan;  Shi, Zhonglin;  Hu, Anzhong;  Cui, Junsheng;  Yang, Ke
  |  收藏  |  浏览/下载:63/0  |  提交时间:2022/05/16
Subcooled water flow boiling heat transfer in screw cooling tubes under one-sided heating conditions 期刊论文  OAI收割
APPLIED THERMAL ENGINEERING, 2017, 卷号: 113, 期号: 无, 页码: 621-631
作者:  
Liu, P.;  Peng, X. B.;  Song, Y. T.;  Mao, X.
收藏  |  浏览/下载:24/0  |  提交时间:2018/05/02
Analysis of polymorphisms of genes associated with folate-mediated one-carbon metabolism and neural tube defects in Chinese Han Population 期刊论文  OAI收割
BIRTH DEFECTS RESEARCH PART A-CLINICAL AND MOLECULAR TERATOLOGY, 2016, 卷号: 106, 期号: 4, 页码: 232-239
作者:  
Piao, Wei;  Guo, Jin;  Bao, Yihua;  Wang, Fang;  Zhang, Ting
收藏  |  浏览/下载:30/0  |  提交时间:2016/07/14
1D-KBA microscope using double-periodic multilayer (EI CONFERENCE) 会议论文  OAI收割
Advances in X-Ray/EUV Optics and Components IV, August 3, 2009 - August 5, 2009, San Diego, CA, United states
作者:  
Wang Z.;  Wang X.;  Wang X.;  Wang X.;  Wang Z.
收藏  |  浏览/下载:11/0  |  提交时间:2013/03/25
To study the action of shock wave in CH target  one-dimensional grazing incidence KBA microscope for 4.75keV energy was set up. Because of strong absorption in air  4.75keV energy microscope can just work in vacuum. Accordingly  the alignment and assemblage will be very complicated and difficult. A special multilayer method  using double periodic multilayer  was proposed to solve this problem. This multilayer has high reflectivity not only for 4.75keV X-rays but also for 8keV X-rays at the same grazing incidence angle. It means 1D-KBA microscope has the same light trace for different working energies. Therefore  we can implement the alignment and assembly of 4.75keV system by the help of 8keV X-rays. Because 8keV X-rays is very easy produced by X-ray tube and has strong transmittability in air  the alignment and assemblage process became relatively easy. By now  we have finished the alignment experiment at 8keV and obtained imaging results. The performance is about 2-3m resolution in 250m field of view. It is coincide with the calculation. 2009 SPIE.  
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
作者:  
Song K.-F.;  Li J.-L.;  Zhang W.-L.;  Wang Y.-L.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
In the device  a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source  and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system  so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least  the sample fluorescence through the integrating sphere and come to the grating monochromator  The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device  SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process  signal-to-noise ratio(SNR) will be improved  also adjust delay time  ampling frequency and sampling number arbitrarily. By testing  the sensitivity is 10-12mol/L(substance marked by Eu3+)  examination repeat is &le2.5%  examination linearity is from 10 -8mol/L to 10-12mol/L  correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody  and solve the tumor  genetic variation  the virus protein detection. 2009 SPIE.