中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共13条,第1-10条 帮助

条数/页: 排序方式:
Effect of subreflector displacement induced aberrations for dual-reflector antenna 会议论文  OAI收割
Taiyuan, China, July 18, 2019 - July 19, 2019
作者:  
Xiang, Binbin;  Lian, Peiyuan;  Wang, Wei;  Xue, Fei;  Kazezkhan, Guljaina
  |  收藏  |  浏览/下载:22/0  |  提交时间:2021/04/12
Piecewise Linear Weighted Iterative Algorithm for Beam Alignment in Scanning Beam Interference Lithography 期刊论文  OAI收割
Photonic Sensors, 2019, 卷号: 9, 期号: 4, 页码: 344-355
作者:  
Y.Song;  Bayanheshig;  S.Li;  S.Jiang;  W.Wang
  |  收藏  |  浏览/下载:35/0  |  提交时间:2020/08/24
Nonrotationally symmetric aberrations of off-axis two-mirror astronomical telescopes induced by axial misalignments 期刊论文  OAI收割
Applied Optics, 2018, 卷号: 57, 期号: 6, 页码: 1399-1409
作者:  
Ju, G. H.;  Yan, C. X.;  Gu, Z. Y.;  Ma, H. C.
  |  收藏  |  浏览/下载:12/0  |  提交时间:2019/09/17
Method for measurement of eccentricity and tilt of lenslet array integral field spectrometer 期刊论文  OAI收割
Applied Optics, 2018, 卷号: 57, 期号: 34, 页码: F50-F55
作者:  
Liu, J. N.;  Chen, J. J.;  Liu, J. L.;  Feng, S. L.;  Yang, J.
  |  收藏  |  浏览/下载:2/0  |  提交时间:2019/09/17
Computation of misalignment and primary mirror astigmatism figure error of two-mirror telescopes 期刊论文  OAI收割
Journal of Astronomical Telescopes Instruments and Systems, 2018, 卷号: 4, 期号: 1, 页码: 10
作者:  
Gu, Z. Y.;  Wang, Y.;  Ju, G. H.;  Yan, C. X.
  |  收藏  |  浏览/下载:161/0  |  提交时间:2019/09/17
Convex blazed grating of high diffraction efficiency fabricated by swing ion-beam etching method 期刊论文  OAI收割
Optics Express, 2018, 卷号: 26, 期号: 19, 页码: 25381-25398
作者:  
Shen, C.;  Tan, X.;  Jiao, Q. B.;  Zhang, W.;  Wu, N.
  |  收藏  |  浏览/下载:26/0  |  提交时间:2019/09/17
Aberration fields of off-axis astronomical telescopes induced by rotational misalignments 期刊论文  OAI收割
Optics Express, 2018, 卷号: 26, 期号: 19, 页码: 24816-24834
作者:  
Ju, G. H.;  Ma, H. C.;  Yan, C. X.
  |  收藏  |  浏览/下载:24/0  |  提交时间:2019/09/17
Nanoscale patterns made by using a 13.5-nm Schwarzschild objective and a laser produced plasma source (EI CONFERENCE) 会议论文  OAI收割
Optical Micro- and Nanometrology IV, April 16, 2012 - April 18, 2012, Brussels, Belgium
作者:  
Wang X.;  Wang X.;  Wang X.;  Wang Z.;  Wang Z.
收藏  |  浏览/下载:42/0  |  提交时间:2013/03/25
Lithium fluoride (LiF) crystal is a very promising candidate as nanometer resolution EUV and soft X-ray detector. Compared with other EUV and soft X-ray detectors  charge coupled device and photographic films  LiF crystal has high resolution  large field of view and wide dynamic range. In this paper  using LiF crystal as EUV detector and a Schwarzschild objective (SO) working at 13.5nm as projection optics  mesh images with 4.2 m  1.2 m and 800 nm line width and pinhole patterns with 1.5m diameter are acquired in projection imaging mode and direct writing mode  respectively. Fluorescence intensity profiles of images show that the resolution of mesh image is 900 nm  and the one of pinhole image is 800 nm. In the experiments  a spherical condense mirror based on normal incidence type is used to eliminate the damage and contamination on the masks (mesh and pinhole) caused by the laser plasma  and the energy density is not decreased compared with that the masks are close to the plasma. The development of the SO  the alignment of the objective and the imaging experiments are also reported. 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  
The optical design of cubic phase plate testing system (EI CONFERENCE) 会议论文  OAI收割
2011 Symposium on Photonics and Optoelectronics, SOPO 2011, May 16, 2011 - May 18, 2011, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.;  Zhang Y.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/25
Computer-generated holograms (CGH) have been widely used for years in optical testing of aspheric surfaces in combination with Fizeau interferometers. With the development of diffraction optics  computer technology  and micro-processing technology  the accuracy of the CGH testing can achieve a hundredth of a wave  and the cost is reduced greatly. CGH is capable of producing an optical wavefront with any desired shape. So it is fascinating and will have good prospects to test free-form surfaces using CGH. As the CGH can create any wavefront shape  it can also be used in unsymmetrical aspherical surfaces testing. Taking the cubic surface as an example  this paper gives a method to test unsymmetrical surfaces. This paper gives the design to test a cubic surface. And the separation of the diffraction orders and the binary process of the continuous CGH phase function are discussed in detail. The alignment tolerance of the test system and the CGH fabrication tolerance are analyzed. We also present an idea using a CGH and two spherical lenses as null lens to test the cubic surface when the surface deviation is great. 2011 IEEE.  
Realization of double resonance for a bright frequency-tunable source of narrowband entangled photons 期刊论文  OAI收割
CHINESE PHYSICS B, 2011, 卷号: 20, 期号: 2
作者:  
Yang Jian;  Zhao TianMing;  Zhang Han;  Yang Tao;  Bao XiaoHui
  |  收藏  |  浏览/下载:24/0  |  提交时间:2021/12/13