中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共11条,第1-10条 帮助

条数/页: 排序方式:
Extraction of Multiple Electrical Parameters From IP-Affected Transient Electromagnetic Data Based on LSTM-ResNet 期刊论文  OAI收割
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2023, 卷号: 61, 页码: 14
作者:  
Zhang, Shun;  Zhou, Nannan
  |  收藏  |  浏览/下载:17/0  |  提交时间:2023/12/29
Non-line-of-Sight Imaging via Neural Transient Fields 期刊论文  OAI收割
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2021, 卷号: 43, 期号: 7, 页码: 2314-2328
作者:  
Zhong, Zhao;  Yang, Zichen;  Deng, Boyang;  Yan, Junjie;  Wu, Wei
  |  收藏  |  浏览/下载:44/0  |  提交时间:2021/08/15
Nonlinear Optical Studies of Gold Nanoparticle Films 期刊论文  OAI收割
Nanomaterials, 2019, 卷号: 9, 期号: 2, 页码: 10
作者:  
A.Rout;  G.S.Boltaev;  R.A.Ganeev;  Y.Fu;  S.K.Maurya
  |  收藏  |  浏览/下载:30/0  |  提交时间:2020/08/24
Comparison of single-event transients of t-gate core and io device in 130nm partially depleted silicon-on-insulator technology 期刊论文  iSwitch采集
Ieice electronics express, 2016, 卷号: 13, 期号: 12, 页码: 11
作者:  
Zheng Yunlong;  Dai Ruofan;  Chen Zhuojun;  Sun Shulong;  Wang Zheng
收藏  |  浏览/下载:47/0  |  提交时间:2019/05/09
Performance test of steel tube enclosed thermistors in air temperature measurements (EI CONFERENCE) 会议论文  OAI收割
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
作者:  
Yang H.;  Yan F.;  Yan F.;  Peng J.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
The performances of two steel tube enclosed precision thermistors are tested in a well controlled air environment to determine if the thermistors have enough accuracy for 0.01C levels of air temperature gradient measurement. Three Fluke's 5641 and three 5610 thermistors were tested for 24 hours in Fluke's 7008 calibration bath in the first step. In the second step  the performances of these two thermistors in steady state and transient state air temperature environments were tested for 8 hours separately. The results illustrate that  two of the 5641s were airproofed in a temperature well controlled tube  when steel tube enclosed precision thermistors are used in air temperature measurement  there are unstable departures from each other with a maximum 8.8 mC in constant air medium and 27 mC in temperature changing air medium. The transient-time errors are too large to show the true amounts of temperature changes for air temperature measurement. 2011 IEEE.  
The Design Criteria of Storage-Adjustable Transient Pulse Method for Large Range Permeability Measurement 会议论文  OAI收割
Hong Kong, PEOPLES R CHINA, FEB 20-21, 2011
作者:  
Wang, Ying;  Li, X. C.;  Wei, N.;  Xiao, Wenlian
  |  收藏  |  浏览/下载:24/0  |  提交时间:2018/06/05
Characteristics of ZnMgO-based metal-semiconductor-metal photodetectors (EI CONFERENCE) 会议论文  OAI收割
International Symposium on Photoelectronic Detection and Imaging, ISPDI 2007: Photoelectronic Imaging and Detection, September 9, 2007 - September 12, 2007, Beijing, China
作者:  
Zhang J.;  Li B.;  Li B.;  Li B.;  Zhao Y.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
In recent years  ZnMgO semiconductor alloys  with a direct bandgap tunable between 3.37 eV and 7.8 eV  become one of the most suitable materials for the fabrication of ultraviolet detectors. In this paper  we have fabricated metal-semiconductor-metal photodetectors on 1-m thick Zn 0.8Mg0.2O films. The interdigital metal electrodes are 500 m long and 5 m wide with an interelectrode spacing 2 m  5 m and 10 m  respectively. Zn0.8Mg0.2O films were grown on quartz by ratio frequency magnetron sputtering at 500C. Dark current  spectral responsivity and pulse response were carried out for the devices with different finger pitches. All the photodetectors showed the peak responsivity at 330 nm and the ultraviolet-visible rejection ratio (R330 nm/R400 nm) is more than four orders of magnitude at 3 V bias. For the device with 2 m finger pitch  the detectivity was calculated as 4.21011 cm Hz 1/2/W at 330 nm. Furthermore  the transient response measurement for all devices revealed similar rise time of 10 ns. The 90%-10% fall times are 130 ns  170 ns and 230 ns for the devices with different finger pitches of 2 m  5 m and 10 m  respectively..  
Application of chemical ionization mass spectrometry in in situ measurement of atmospheric trace species 期刊论文  OAI收割
progress in chemistry, 2007, 卷号: 19, 期号: 2-3, 页码: 377-384
作者:  
Dong Can;  Hou Keyong;  Wang Junde;  Li Haiyang
收藏  |  浏览/下载:24/0  |  提交时间:2015/11/11
An experimental study of temperature and moisture content of wet porous materials under short-pulsed laser heating 期刊论文  OAI收割
JOURNAL OF UNIVERSITY OF SCIENCE AND TECHNOLOGY BEIJING, 2005, 卷号: 12, 期号: 5, 页码: 476-480
作者:  
Jin, RX;  Huai, XL
收藏  |  浏览/下载:20/0  |  提交时间:2015/12/17
Study of rapid transient explosive boiling under short-pulsed laser heating 期刊论文  OAI收割
PROGRESS IN NATURAL SCIENCE, 2004, 卷号: 14, 期号: 8, 页码: 700-704
作者:  
Jin, RX;  Huai, XL
收藏  |  浏览/下载:19/0  |  提交时间:2015/12/17