中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共10条,第1-10条 帮助

条数/页: 排序方式:
Text-to-Image Vehicle Re-Identification: Multi-Scale Multi-View Cross-Modal Alignment Network and a Unified Benchmark 期刊论文  OAI收割
IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2024, 页码: 14
作者:  
Ding, Leqi;  Liu, Lei;  Huang, Yan;  Li, Chenglong;  Zhang, Cheng
  |  收藏  |  浏览/下载:23/0  |  提交时间:2024/03/27
Skeleton-Based Action Recognition With Key-Segment Descriptor and Temporal Step Matrix Model 期刊论文  OAI收割
IEEE ACCESS, 2019, 卷号: 7, 页码: 169782-169795
作者:  
Li, Ruimin;  Fu, Hong;  Lo, Wai-Lun;  Chi, Zheru;  Song, Zongxi
  |  收藏  |  浏览/下载:20/0  |  提交时间:2020/10/30
Skeleton-Based Action Recognition with Key-Segment Descriptor and Temporal Step Matrix Model 期刊论文  OAI收割
IEEE Access, 2019, 卷号: 7, 页码: 169782-169795
作者:  
Li, Ruimin;  Fu, Hong;  Lo, Wai-Lun;  Chi, Zheru;  Song, Zongxi
  |  收藏  |  浏览/下载:35/0  |  提交时间:2020/02/28
Group Sparse Multiview Patch Alignment Framework With View Consistency for Image Classification 期刊论文  OAI收割
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2014, 卷号: 23, 期号: 7, 页码: 3126-3137
作者:  
Gui, Jie;  Tao, Dacheng;  Sun, Zhenan;  Luo, Yong;  You, Xinge
收藏  |  浏览/下载:26/0  |  提交时间:2015/08/12
Design and fabrication of imaging optical systems with freeform surfaces (EI CONFERENCE) 会议论文  OAI收割
Current Developments in Lens Design and Optical Engineering XIII, August 13, 2012 - August 15, 2012, San Diego, CA, United states
作者:  
Zhang F.;  Wang L.;  Wang L.;  Wang L.;  He X.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
Nanoscale patterns made by using a 13.5-nm Schwarzschild objective and a laser produced plasma source (EI CONFERENCE) 会议论文  OAI收割
Optical Micro- and Nanometrology IV, April 16, 2012 - April 18, 2012, Brussels, Belgium
作者:  
Wang X.;  Wang X.;  Wang X.;  Wang Z.;  Wang Z.
收藏  |  浏览/下载:37/0  |  提交时间:2013/03/25
Lithium fluoride (LiF) crystal is a very promising candidate as nanometer resolution EUV and soft X-ray detector. Compared with other EUV and soft X-ray detectors  charge coupled device and photographic films  LiF crystal has high resolution  large field of view and wide dynamic range. In this paper  using LiF crystal as EUV detector and a Schwarzschild objective (SO) working at 13.5nm as projection optics  mesh images with 4.2 m  1.2 m and 800 nm line width and pinhole patterns with 1.5m diameter are acquired in projection imaging mode and direct writing mode  respectively. Fluorescence intensity profiles of images show that the resolution of mesh image is 900 nm  and the one of pinhole image is 800 nm. In the experiments  a spherical condense mirror based on normal incidence type is used to eliminate the damage and contamination on the masks (mesh and pinhole) caused by the laser plasma  and the energy density is not decreased compared with that the masks are close to the plasma. The development of the SO  the alignment of the objective and the imaging experiments are also reported. 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  
1D-KBA microscope using double-periodic multilayer (EI CONFERENCE) 会议论文  OAI收割
Advances in X-Ray/EUV Optics and Components IV, August 3, 2009 - August 5, 2009, San Diego, CA, United states
作者:  
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
To study the action of shock wave in CH target  one-dimensional grazing incidence KBA microscope for 4.75keV energy was set up. Because of strong absorption in air  4.75keV energy microscope can just work in vacuum. Accordingly  the alignment and assemblage will be very complicated and difficult. A special multilayer method  using double periodic multilayer  was proposed to solve this problem. This multilayer has high reflectivity not only for 4.75keV X-rays but also for 8keV X-rays at the same grazing incidence angle. It means 1D-KBA microscope has the same light trace for different working energies. Therefore  we can implement the alignment and assembly of 4.75keV system by the help of 8keV X-rays. Because 8keV X-rays is very easy produced by X-ray tube and has strong transmittability in air  the alignment and assemblage process became relatively easy. By now  we have finished the alignment experiment at 8keV and obtained imaging results. The performance is about 2-3m resolution in 250m field of view. It is coincide with the calculation. 2009 SPIE.  
Novel algorithm for computer-aided alignment of wide field of view complex optical system (EI CONFERENCE) 会议论文  OAI收割
Yang X.; Han C.
收藏  |  浏览/下载:31/0  |  提交时间:2013/03/25
Development of an experimental EUVL system (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Design, Manufacturing, and Testing of Micro- and Nano-Optical Devices and Systems, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Wang L.-P.;  Zhang L.-C.;  Jin C.-S.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
Design of dual-FOV refractive/diffractive LWIR optical system (EI CONFERENCE) 会议论文  OAI收割
3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies, AOMATT 2007: Advanced Optical Manufacturing Technologies, July 8, 2007 - July 12, 2007, Chengdu, China
作者:  
Wang L.-J.;  Zhang J.-P.;  Wang L.-J.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:33/0  |  提交时间:2013/03/25
An infrared-optical zoom system using binary element is proposed in this paper. The two main advantages of the zoom system introducing here are: bigger F-number and lower cost. The primary optical properties are: F/#=1  Second  Others  zoom ratio =1:4  binary element is used to correct the chromatical aberration by taking the advantage of negative dispersion characteristics and the cost of the system is lower than that of conventional ones with Zinc Selenide (Znse) material at the same level. In the binary element is rotational symmetric with one step which is easy to fabricate  in order to balance 5th spherical aberration  and dual field are 26.6 and 5.6respectively. Wider field of view is used for search and the smaller one is used for imaging details. This system uses un-cooled infrared detector with 320240 pixels and 45m pixel size. The F-number matches the sensitivity range of the detector array. Three aspects are considered during design process to make the system more satisfactory and more achievable. First  5th coma aberration and 5th astigmatic aberration  the manner of zoom is accomplished by exchanging tow lenses into the smaller field of view system layout. The lens exchange manner faces the requirement of simple system structure and good image quality in both focal points. It can also make the system more feasible in the alignment process than mechanical-zooming manner and optical-zooming manner  high-order asphere surfaces with 2th order to 10 th order are also hired in the system. Asphere surface is useful in compressing the system and improving optical system transmittance. This kind asphere surface is on industrial level featuring low cost and easy to fabricate. It is shown that good image quality can achieved by implementing five Germanium lenses and the transmittance of system is 72%. All aberrations are diffraction-limited  both spherical aberration and astigmatic aberration are corrected. When the field of view(FOV) is 26.6 and the focal length is 152mm  MTF at Nyquist frequency(11lp/mm) is great than 0.7. The spherical aberration is -0.0073. The coma aberration is 0.0978 and the astigmatic aberration is -0.013. When the field of view(FOV) is 5.6 and the focal length is 38mm  MTF at Nyquist frequency is great than 0.8 with spherical aberration -0.0046  the coma aberration 0.055 and astigmatic aberration 0.034.