中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共19条,第1-10条 帮助

条数/页: 排序方式:
Development of in-situ anisotropic deformation characteristics detection equipment for loess hole 期刊论文  OAI收割
MEASUREMENT, 2025, 卷号: 243, 页码: 18
作者:  
Zhang, Yaozhong;  Zhang, Hongbing;  Yan, Changgen;  Lan, Hengxing;  Liu, Xin
  |  收藏  |  浏览/下载:10/0  |  提交时间:2025/03/03
High-Precision Automatic Calibration Modeling of Point Light Source Tracking Systems 期刊论文  OAI收割
SENSORS, 2021, 卷号: 21
作者:  
Li, Ruijin;  Zhang, Liming;  Wang, Xianhua;  Xu, Weiwei;  Li, Xin
  |  收藏  |  浏览/下载:33/0  |  提交时间:2021/05/17
A Novel Camera Calibration Method Based on Multilevel-Edge-Fitting Ellipse-Shaped Analytical Model 期刊论文  OAI收割
IEEE Sensors Journal, 2020, 卷号: 20, 期号: 11, 页码: 5818-5826
作者:  
Su S(苏顺);  Luo Y(罗阳);  Yang KK(杨克克);  Gao ZY(高振远);  Zhao YW(赵忆文)
  |  收藏  |  浏览/下载:9/0  |  提交时间:2020/05/30
Design and investigation of absolute radiance calibration primary radiometer 期刊论文  OAI收割
IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 卷号: 12, 期号: 8, 页码: 994-1000
作者:  
Wang Yupeng;  Xia Zhiwei;  Luo Yang;  Wang Kai;  Fang Wei
  |  收藏  |  浏览/下载:74/0  |  提交时间:2019/08/26
Evaluation of different calibration equations for NTC thermistor applied to high-precision temperature measurement 期刊论文  OAI收割
Measurement, 2018, 卷号: 120, 页码: 21-27
作者:  
Liu, G.;  Guo, L.;  Liu, C. L.;  Wu, Q. W.
  |  收藏  |  浏览/下载:14/0  |  提交时间:2019/09/17
Analysis and calibration of precision for point source transmittance system 期刊论文  OAI收割
acta physica sinica, 2016, 卷号: 65, 期号: 11
作者:  
Li Zhao-Hui;  Zhao Jian-Ke;  Xu Liang;  Liu Feng;  Guo Yi
收藏  |  浏览/下载:21/0  |  提交时间:2016/10/10
High accuracy three-dimensional attitude angle measuring device 期刊论文  OAI收割
guangxue jingmi gongcheng/optics and precision engineering, 2016, 卷号: 24, 期号: 5, 页码: 963-970
作者:  
Sun, Guo-Yan;  Gao, Li-Min;  Bai, Jian-Ming;  Yang, Dong-Lai;  Pan, Liang
收藏  |  浏览/下载:26/0  |  提交时间:2016/10/13
High Precision Automatic Assembly Based on Microscopic Vision and Force Information 期刊论文  OAI收割
IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2016, 卷号: 13, 期号: 1, 页码: 382-393
作者:  
Liu, Song;  Xu, De;  Zhang, Dapeng;  Zhang, Zhengtao
  |  收藏  |  浏览/下载:22/0  |  提交时间:2016/10/20
Theoretical analysis on optical parallelism of pentaprism 期刊论文  OAI收割
ACTA PHOTONICA SINICA, 2015, 卷号: 44, 期号: 5, 页码: 523006
作者:  
Wang QS(王秋实);  Li M(李明);  Liao KL(廖可梁);  Yang FG(杨福桂);  Sheng WF(盛伟繁)
收藏  |  浏览/下载:65/0  |  提交时间:2016/04/18
Design of the real-time autofocusing system for collimator with long focus length and large aperture (EI CONFERENCE) 会议论文  OAI收割
2011 International Academic Conference on Numbers, Intelligence, Manufacturing Technology and Machinery Automation, MAMT 2011, December 24, 2011 - December 25, 2011, Wuhan, China
作者:  
Zhang X.;  Zhang X.;  Zhang X.
收藏  |  浏览/下载:39/0  |  提交时间:2013/03/25
Large aperture collimator which has been widely used for calibrating and testing various optical devices plays an essential role in correlative laboratories. As being the basic testing and calibration equipment  the large aperture collimator's accuracy should be much higher than the device under testing in order to ensure the accuracy of the measurement. However  the process of adjusting the collimator is extremely complicated due to the collimator's large aperture and long focal length. So it is difficult to ensure the measurement's quality and easy to cause the system being vulnerable to the surrounding environment. One of the most common problems is defocus. In order to solve the problem above  this issue presents a new type of autocollimator autofocusing system which uses pentaprism instead of using large-aperture plane mirror  semiconductor lasers as light source and CCD sensor as receiver. The system is smaller  lighter  and more convenient when using. The computer simulation shows that the autofocusing system's resolution could reach the accuracy of 40m. If we use the relevant algorithms to execute the sub-pixel scanning  the resolution could reach the accuracy of 10m. It shows that the system could satisfy the required testing precision of testing large aperture optical device.