中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
机构
采集方式
内容类型
发表日期
学科主题
筛选

浏览/检索结果: 共16条,第1-10条 帮助

条数/页: 排序方式:
Design and Testing of the Front-End Electronics of WCDA in LHAASO 期刊论文  OAI收割
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 卷号: 68, 期号: 8, 页码: 2257-2267
作者:  
Aharonian, F.;  An, Q.;  Axikegu;  Bai, L. X.;  Bai, Y. X.
  |  收藏  |  浏览/下载:101/0  |  提交时间:2021/09/10
Augmented fixed-time observer-based continuous robust control for hypersonic vehicles with measurement noises 期刊论文  OAI收割
IET CONTROL THEORY AND APPLICATIONS, 2019, 卷号: 13, 期号: 3, 页码: 422-433
作者:  
Sun, Jinlin;  Yi, Jianqiang;  Pu, Zhiqiang
  |  收藏  |  浏览/下载:72/0  |  提交时间:2019/07/12
Feedforward Control for Wind Turbine Load Reduction with Pseudo-LIDAR Measurement 期刊论文  OAI收割
International Journal of Automation and Computing, 2018, 卷号: 15, 期号: 2, 页码: 142-155
作者:  
Jie Bao
  |  收藏  |  浏览/下载:17/0  |  提交时间:2021/02/23
Single-outcome information gain of qubit measurements on different state ensembles 期刊论文  OAI收割
JOURNAL OF PHYSICS A-MATHEMATICAL AND THEORETICAL, 2014, 卷号: 47, 期号: 30
Ren, XJ; Fan, H
收藏  |  浏览/下载:21/0  |  提交时间:2015/04/14
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Wang J.;  Liu Y.;  Liu Y.;  Liu Y.;  Sun Q.
收藏  |  浏览/下载:27/0  |  提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation  the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results  the reference gains and the dynamic range of temperature measurement were obtained. Finally  the uncertainty influencing the calibration results was analyzed  the analysis shows the maximal uncertainty is 5.2%  which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Autocollimation form dual-frequency laser diffraction grating interferometer design and analysis (EI CONFERENCE) 会议论文  OAI收割
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Wang C.-G.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
Propose a new measurement system of autocollimation form laser grating heterodyne interferometer. Take grating diffraction and polarization optics as theoretical foundation  second  furthermore  combined with electronics knowledge to analyze the system. First  make use of autocollimation diffraction of grating  measurement information obtained by dual-frequency laser belongs to ac signal  the interferometer measurement system take grating pitch as measuring datum  the structure is simple  possess great gain and high signal-noise ratio  therefore  stable  completely overcome the disadvantages of DC level drift caused by light intensity variation of single-frequency laser  system can achieve nanometer resolution. 2010 IEEE.  reduce the impact of environmental factors  easy to install and debug  measurement error is small  
Linearity measurement for image-intensified CCD (EI CONFERENCE) 会议论文  OAI收割
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
作者:  
Zhang L.;  Zhao Y.;  Zhao Y.;  Zhao Y.;  Yan F.
收藏  |  浏览/下载:34/0  |  提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)  technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed  and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system  and calibration of the filters' transmittance in different working positions has been done. Meanwhile  to assure the uniform of the received radiation on the target of the detector at any test points  an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization  the attenuation film with transmission  integrating sphere  optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument  the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Optical amplification near 1300 nm in bismuth-doped strontium germanate glass 期刊论文  OAI收割
j. opt. soc. am. b-opt. phys., 2007, 卷号: 24, 期号: 10, 页码: 2597, 2600
任进军; 乔延波; 朱从善; 姜雄伟; 邱建荣
收藏  |  浏览/下载:1239/210  |  提交时间:2009/09/24
A calculation method to eliminate gain effect on isotopic measurement using the virtual amplifier multi-collector mass spectrometer 期刊论文  OAI收割
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 卷号: 253, 期号: 1-2, 页码: 130-135
作者:  
Chu, Zhuyin;  Yang, Yueheng;  Qiao, Guangsheng
  |  收藏  |  浏览/下载:18/0  |  提交时间:2018/09/26
A calculation method to eliminate gain effect on isotopic measurement using the virtual amplifier multi-collector mass spectrometer 期刊论文  OAI收割
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 卷号: 253, 期号: 1-2, 页码: 130-135
作者:  
Chu, Zhuyin;  Yang, Yueheng;  Qiao, Guangsheng
  |  收藏  |  浏览/下载:19/0  |  提交时间:2018/09/26